Page 1
lant utomatic ontroller e f e R e n c e a n u a l...
Page 2
VRA or the console keys - to match field conditions. The ProPlant has been designed for easy installation and op er a tion. How ev er, since each in stal la tion will vary depending on your equipment, please take time to fa mil iar ize yourself with this manual and the actual components before beginning.
Eagle Lake, MN 56024-0099 At Micro-Trak® Systems, we believe a product that delivers quality and performance at a reasonable cost is what is needed to help today’s operator and the operator of the future compete in the world mar ket.
Component Parts and Assembly Hardware (single and multiple drive) ..............5-6 Component Parts - Hydraulic Planter Drive Kit ........................7 ProPlant Single Drive Mounted System Layout ........................8 ProPlant Single Drive Mounted Wiring Diagram ........................ 9 ProPlant Single Drive Drawn System Layout........................10 ProPlant Single Drive Drawn Wiring Diagram........................
Before beginning installation, check the carton contents for the following items: lant e f e R e n c e a n u a l Console Mount Kit ProPlant Console Reference Manual 20’ Section Harness (one section) P/N 13774 P/N 17289...
Page 6
Before beginning installation, check the carton contents for the following items: lant e f e R e n c e a n u a l Section Branch Harness Console Mount Kit ProPlant Console Reference Manual (Sections 1-3) P/N 13774 P/N 17289 P/N 17329 P/N 17307 20’...
Position console to proper viewing angle and tighten the knobs securely. Electrical Installation Illustration 2 The ProPlant must be connected to a 12-volt DC elec tri cal 20-Amp In-line Ground (ORANGE) Fuse Required system.
Magnetic Speed Sensor Installation the wheel or drive shaft begins turning, a speed impulse is sent to the ProPlant console every time a magnet passes by Please Note: If you have purchased an Astro 5 GPS Speed the tip of the speed sensor. For the speed sensor to operate...
See ProPlant Wiring Diagram on pages 9, 11, 13, or 15. Speed Sensor Options The ProPlant may be interfaced with a va ri ety of speed sensing equipment. Several options are listed below. Astro Series or other GPS Speed Sensor Interfaces...
HOLD. Sensor (Black body) Care & Maintenance of your ProPlant Console • Store the console in a cool dry location if it will not be used for an extended period of time, such as during the off-season.
Installation (cont) Calculating Planter Drive Ratio The value for Driven or Drive Sprocket refers to the number Calculating your Flow Cal for a Planter Drive of teeth on the sprocket. Rows equals the number of rows the drive is running. ROWS = ______ To calculate Ratio for a single stage chain drive, use the following equation:...
Installation (cont) Installing the Planter Drive Choose a location between row units for the tool bar Loosen the four 3/8” flange bolts installed in step 2. mount bracket approximately five inches to the left Locate the full threaded 1/2” by 3” bolt, 1/2” jam nut of a hex shaft hanger bearing to the center of the tool and 1/2”...
Installation (cont) Installing the Planter Drive (cont) Calculate your Hydraulic Oil Needs • (MPS x 5280) x 12 = Inches traveled per hour (5 x 5280) x 12 = 316800 inches traveled per hour What is your Maximum Planting Speed in miles per •...
ProPlant Console Func tions The ProPlant features two large, easy-to-read liquid crystal displays and a lighted panel for night use. The right-hand display always shows the application rate and the left-hand display shows data selected by the rotary switch. Press the On/Off button to turn console on or off.
Illustration 5 Loading Default Calibration Values CAL HOLD English or Metric? V 1 2 3 4 5 HOLD SEED RATE The ProPlant is capable of displaying in for ma tion in SEEDS AREA METER ROWS (1) (2) (3) (1) (2) (3) SECTION Amer i can En glish or standard Metric measurement.
SPEED CAL number, see Appendix A on page 41. If the test is a success, you have successfully calibrated Illustration 7 your ProPlant drive assembly, if not check the following settings: In “Special” Cal, check the Ratio and Motor Cal settings...
When a typical “1.0” is entered, you SEED ADJUST operating speed is entered, the ProPlant will respond as if you SPACING RATE will be able to increase were actually driving that speed. It allows you...
“Special” Calibration “Special” Cal “Special” Cal General AUTO The “Special” Calibration mode is used to set up system Units Ratio parameters that rarely need to be changed or adjusted. To SEEDS AREA METER ROWS enter Special Cal, put the system in HOLD, turn the console (1) (2) (3) (1) (2) (3) SECTION...
DISTANCE (1) (2) (3) SPACING SEED AREA / ADJUST METER CAL SPACING The ProPlant can be operated in Manual (MAN) or Automatic RATE HOUR TEST ON / OFF SEEDS / TEST TARGET (AUTO) mode. In either mode, the right-hand display will...
Operation (cont) Automatic Operation Turn rotary dial to display desired readout. When the Automatic mode is selected, the console will control the control valve to maintain the desired seed rate SPA (SPH) when the vehicle speed changes or when sections are turned on or off. Press the AUTO/MAN button to select AUTOMATIC mode;...
Operation (cont) Resetting System Counters AUTO HOLD SEED RATE The AREA, DISTANCE and SEED counters maintain a running SEEDS AREA METER ROWS (1) (2) (3) (1) (2) (3) SECTION count during operation regardless of the position of the SPEED DISTANCE (1) (2) (3) SPACING rotary switch.
Run/Hold switch or sensor and connections. The ShAFt Err message described above will ash for 5 seconds and if the ProPlant is in AUTO, the system runs the control valve in the open direction in an e ort to generate an RPM signal.
If you have a two-way radio, it may be mounted too close to related to equipment failure, PLEASE DO NOT OPEN THE the console. Keep all ProPlant cables away from the radio, its CONSOLE. Your system is protected by a warranty, and antenna and power cable.
5. Holding the tip of either the Speed or Run/Hold sensor connectors. up to the north pole of a magnet (non-perforated side of a Micro-Trak magnet) the meter should read a very ELECTRICAL INTERFERENCE high resistance, while holding the tip of the sensor up...
Troubleshooting (cont) Troubleshooting Console Inputs & Outputs SPEED INPUT CONTROL VALVE OUTPUT Turn the rotary switch to the Speed position and perform the To test the Control Valve Output, perform the following following procedure: procedure: Set operating mode to Manual (MAN). Disconnect the Speed sensor (yellow tie) Toggle the console Run/Hold switch to Run.
Appendix A Fine Tuning Speed/Distance Calibration Val ue This procedure is used to verify the speed/distance calibration. With the rotary dial still at DISTANCE (SPEED CAL), press In order to achieve accurate measurements, each step in this and hold the “CAL” key for one second. Once the con- fine tuning procedure should be performed as precisely as sole is in “CAL,”...
Appendix C Conversion Chart English to Metric Metric to English When You Know Multiple By To Find When You Know Multiple By To Find LINEAR MEASUREMENT LINEAR MEASUREMENT inches 25.4 millimeters millimeters .039 inches feet 0.305 meters meters 3.28 feet yards 0.914 meters...
Appendix D Replacement Parts List The following replacement parts are available from your dealer or distributor. To find your nearest dealer or distributor, visit www.micro-trak.com or call Micro-Trak at 1-800-328-9613. Micro-Trak Systems, Inc. P .O. Box 99, 111 East LeRay Avenue...
Appendix E VRA (Variable Rate Application) To perform Variable Rate Application, a token (Micro-Trak P/N # 17370) must be inserted into the back of the ProPlant console, as shown. (Remove the label covering the socket. Serial Memory Token Turn power off before inserting or removing the token.)
Need help?
Do you have a question about the ProPlant and is the answer not in the manual?
Questions and answers