Honeywell Lyric RF6GB Installation Instructions page 2

Glassbreak smart sensor

Advertisement

Enroll
This device can be enrolled and
programmed either before or after
installation.
1.
Set the Lyric Smart Controller in
Programming Mode.
2. Remove the battery tab to activate the
device and begin the enrollment
process.
3. The RF6GB Green LED flashes during
enrollment (about 8 seconds*)
*Note: Depending on the signal strength
between the device and the control, the
enrollment period may take longer than 8
seconds.
• The device sends its unique MAC ID
address (Serial Number) and Services
information to the control.
• The control registers the device and
displays the transmitter data on
screen.
4. Enrollment is confirmed When the
RF6GB Green LED is ON for 3 seconds
[and the control beeps
5. If the sensor is not successfully enrolled
during the enrollment period, the LED
turns off and the device powers down.
Activate the tamper, power down and
up again, or use the FG701 Glassbreak
Simulator to restart the enrollment
process.
Program the RF6GB
Consult the Control's instructions for
programming the device in the system.
Fault device features to "Learn" device
"Services" in the control:
-
Tamper switch
-
Selectable Sensitivity Settings
-
Temperature sensing
Temperature Sensing
Temperature sensing range is 0 – 50°C /
32 – 122°F and is always enabled. Program the
system to use the temperature information at
the panel.
TBD].
Note: Once enrolled in a system, the detector cannot be used with
another control panel until it is removed from the current control
panel. See the Control's instructions for details on removing
devices.
Sensitivity Setting
High
Medium
Low
Lowest
The RF6GB detector is Factory set at HIGH
sensitivity. Change the sensitivity setting at
the Control Panel.
Approximate Range
4.6-7.6m / 15-25 ft.
3-4.6m / 10-15 ft.
1.5-3m / 5-10 ft.
0-1.5m / 0-5 ft.