Specifications

Heater
Type
Power
Operating Speed
Engine Controls/Display
Air Volume
Battery
Static Pressure
Air Outlet
Electrical
Engine Fuel
Engine Fuel Capacity
Engine Oil Capacity
Engine Coolant Capacity
Engine Fuel Rate (at 100% prime)
Burner Fuel Rate (at 100% prime)
Run Time
Temperature Rise
Fan
Hitch Type
Duct Diameter
Estimated Heater Efficiency
Dimensions
Weight
Burner
Generator
Owner's Manual for Indirect Fired Heater
1,200,000 BTU/hour (351.69 kW/hour) maximum
Indirect fired
ISUZU 3CE1 Tier 4 Final diesel, 23.4 HP (17.4 kW)
1,800 rpm
LOFA, keyed ignition switch
3
6,500 CFM (11,044 m
/hour)
Standard: 575 CCA (115 CCA Reserve)
Cold Weather Package: EON dry cell, 1150 CCA
3 in H
O
2
1 x 20 in (50.8 cm)
12V
Diesel
USA — 270 gal (1022 L)
7.1 qt (6.7 L)
2.1 qt (2 L)
1.25 gph (4.76 Lph)
10.18 gph (38.5 Lph)
33.8 hours
180 °F (82 °C)
Class 2, SWSI, 222 BC
Electric, 2-5/16 in ball coupler
1 x 20 in (50.8 cm)
85%
255 in x 96 in x 102 in (6.5 m x 2.4 m x 2.6 m)
Dry: 8,265 lbs (3,749 kg)
Operating: 10,280 lbs (4,663 kg)
Riello RL38/M
Marathon 282PSL1704
General Information