Regulation Of Primary Air - Smeg GKC955 Instruction Manual

Smeg range instruction manual
Table of Contents

Advertisement

5.3 Regulation for G25/25 mbar
The hob has been inspected for G25 (2L) at a pressure of 25 mbar. To
allow the unit to work with this type of gas, perform the same operations
described in paragraph "5.2 Regulation for LPG", but choose the nozzles
and regulate the primary air for natural gas, as shown in the following
table and in paragraph "5.4 Regulation of primary air". After the
regulations have been carried out, restore the seals with sealing wax or
equivalent material.
Burner
Auxiliary (1)
Semi-rapid (2)
Rapid (3)
Double crown
internal (4)
internal (4)
5.4
Referred to distance "X" in mm.
BURNER
Auxiliary
Semi-rapid
(3)
Rapid
Double crown
(*) For burner reference numbers, see page 32.
30
Instructions for the installer
Rated heating
capacity
(kW)
1.05
1.65
3.1
1.05
3.9

Regulation of primary air

(1)
(2)
internal (4)
external (4)
G25 25 mbar
Nozzle diameter
1/100 mm
76
98
130
76
150
G25
25 mbar
1.5
1.5
2.0
3.0
3.0
Reduced flowrate
(W)
380
380
750
380
1200
G30/G31
30/30 mbar
2.0
2.0
9.0
6.0
10.0