Consult local, state, and national agencies regarding specific requirements and regulati ons. Address any further safety, operation and/or maintenance questions to your nearest Leybold Vacuum office. Failure to observe the following precautions could result in serious personal injury.
Page 4
Safety information Never put fingers or foreign matter into the pump's inlet or the Do not touch clearance of cooling fins. If done, it can cause injury. Avoid moisture Install in an area which is not exposed to moisture such as rain or steam.
Page 5
Description SC 5 D Terminal Condenser Electric Cover Cover Shock SC 15 D Single phase SC 15 D Three phase SC 30 D Single phase SC 30 D Three phase Always keep warning stickers clean. If they become dirty or lost, replace them with new ones.
Description Technical Data Model SC 5 D SC 15 D SC 30 D 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz Displacement l · min (swept volume) · h 6.48 10.6 17.6 21.2 Pumping speed l · min ·...
Description 1.3.1 Motor Related Data Motor Related Data SC 5 D Type Single-Phase Induction / Motor 4P / Totally-Enclosed Insulation Class B IP 44 Thermal Protector TP 212 - Automatic Reset Type Power consumption Voltage Rated current 50 Hz –...
Note 5 : Three Phase Motor does not have internal thermal protection. Be sure to install thermal protection like a breaker. 1.3.2 Performance data 1000 60 Hz SC 30 D 50 Hz 60 Hz 50 Hz 60 Hz SC 5 D 50 Hz mbar Torr Inlet Pressure Fig. 5 Pumping speed characteristics GA01423_0102 - 11/2004...
Ventilation Install in a well-ventilated area. Poor ventilation can cause abnormal overheating, fire or failure since the scroll pump is air-cooled. Neccessary ventilated air: SC 5 D over 2 m · min SC 15 D over 4 m · min...
If the floor is unstable, secure the pump by using 4 x Ø 7 mm holes of the pump leg (SC 5 D) or 4 x Ø 11 mm holes of the pump leg (SC 15 D) or 4 x M 10 tap screws on the pump base (SC 30 D).
Be sure to install a reliable main disconnect swtich (or breaker) for Warning emergency stop. In addition, shut off the SC 5 D by turning off the switch on the motor. Failure to do so can cause damage or fire.
Page 19
Installation SC 15 D / 30 D SC 5 D 200-230 V connection 100-115 V connection (EU wiring) (US wiring) Fig. 11 Single-phase connection When you use this pump in Europe This vacuum pump must be equipped with a main disconnect device in accordance with requirements of EN 60204-1.
Page 20
Installation This shows 200-230 V connection. Fig. 12 Electrical connection (SC 5 D) Chart 1: Single-phase specification Recommended breaker capacity - A SC 5 D SC 15 D SC 30 D 100 10.7 100 12.5 115 10.8 200 200 230...
Page 21
Installation Rotation direction of pump is clockwise viewed from motor side Fig. 13 Check rotation direction after wiring Operate pump with inlet opened, and check that air comes out from out let. If you plan to switch the pump ON-OFF with remote control, check the pump's rotation direction before connecting it to the vacuum system.
Installation SC 15 D / 30 D 208-230 V connection 380-460 V connection (delivered to you) Fig. 15 Three-phase connection 2.4.2 Three-phase motors For SC 15 D / 30 D only Warning Be sure to install a reliable main disconnect switch (or breaker) which meets the IEC standard for emergency stop.
Page 23
Installation Be sure to ground. Connect a ground wire to the ground terminal Warning in motor terminal box. Failure to ground can cause bodily injury such as electric shock. You can change to 208-230 V or 380-460 V connection by changing the bus bars.
Page 24
Installation Fig. 16 Electrical connection (SC 30 D - 200 V) Rotation direction of pump is clockwise viewed from motor side Fig. 17 Check rotation direction after wiring Fig. 18 Avoid dropping foreign matter inside Operate pump with inlet opened, and check that air comes out from out let.
Fig. 19 Connection to vacuum system Connection to vacuum system Inlet of SC 5 D is NW 25 and outlet is NW 16. Inlet of SC 15 D is NW 25 and outlet is NW 16. Inlet of SC 30 D is NW 40 and outlet is NW 25.
Operation Pump clean gas Pump clean gas SC 30 D SC 5 D/15 D Fig. 20 Never pump hazardous gases Do not pump hazardous gases to humans, or explosive, flamma Warning ble, toxic or corrosive gases or substances which contain chemi...
Operation Fig. 22 Never alter equipment Never remove or alter safety equipment or insulation parts. Warning Removing or altering this equipment can cause electric shock or bodily injury by rotating objects. Do not operate when the fan cover is removed. Do not operate, when the terminaI cover is removed.
Operation Proceed as follows to start the pump: 1. Close the isolation valve to prevent drawback of debris from the vacu um pump into vacuum chamber. (Open the purge valve if one is instal led). 2. Switch the vacuum pump ON. 3.
Page 29
When supplying nitrogen gas or dry air to the air flush port, set the pressure equivalent to atmospheric pressure while keeping the flow less than 9 l · min for the SC 5 D or 10 l · min for the SC 15 D and SC 15 D.
Page 30
Operation SC 5 D SC 15 D SC 30 D Fig. 24 Position of Air Flush Port GA01423_0102 - 11/2004...
Operation Shut down After vapor is pumped, continue to operate with the Air Flush open for over one hour. If you close Air Flush Port or stop the pump soon after vapor is pumped, condensed moisture remains in the pump, resulting in failure. To prevent the drawback of debris from the vacuum pump into vacuum chamber during shutdown, close the isolation valve (open the purge valve if one is installed).
(or open the purge valve if one is instal led). Warning Allow the pump to cool down before doing maintenance. Performing maintenance immediately after shutdown can cause bodily injury such as burns. SC 5 D/15 D SC 30 D Burn Burn Fig. 25 Warning...
Page 33
Maintenance Electric shock Electric OFF during inspection and maintenance Fan Cover SC 5 D/15 D Electric OFF during inspection and maintenance SC 30 D Fig. 26 GA01423_0102 - 11/2004...
Maintenance Table - Maintenance When the maintenance interval has been reached, contact Leybold to arrange the required maintenance. Never disassemble, reassemble or alter the pump yourself. We are not responsible for any accidents caused by disassembly, assembly or alteration which was done by the user or non specialist.
Leybold Service If you send a pump to Leybold indicate whether the pump is free of sub Contamination stances damaging to health or whether it is contaminated. If it is contami nated also indicate the nature of hazard. To do so, you must use a pre printed form which we shall send to you upon request.
Voltage drops. Check length and size of cable. Motor malfunctions. Inspect and repair. Pump malfunctions. Inspect and repair. only SC 5 D Switchis turned OFF Turn switch ON. only SC 5 D ON-OFF switch is damaged. Replace. Termal protector trips.
Spare parts Spare parts Parts name SC 5 D SC 15 D SC 30 D Major service kit EK870000499 EK870000500 EK870000501 Minor service kit EK870000496 EK870000497 EK870000498 GA01423_0102 - 11/2004...
EC Conformance Declaration We, the Leybold Vacuum GmbH, declare herewith that the products listed below, in the embodiment which we have placed on the market, comply with the applicable EC guidelines. This declaration becomes invalid if modifications are made to the product without consultation with us.
Page 40
Sales and Service: Fax: +49-351-88 55 041 India Export, PA 15632 service@leybold.it Phone: +65-66652910 info@leybold-dresden.de info@leyboldvacuum.com Leybold Vacuum India Pte Ltd. Fax: +65-65668202 www.leybold-dresden.de Sales: A-125 Road No. 30 Field Service Base vacuum@leyboldvac.com.sg Eastern & Central time zones MIDC Wagle Industrial Estate Z.I.Le Capanne...