Leybold vacuum Sogevac SV65 BI FC Operating Instructions Manual

Leybold vacuum Sogevac SV65 BI FC Operating Instructions Manual

Single-stage, oil-sealed rotary vane pump

Advertisement

Sogevac
®
SV40-65 BI FC
Single-stage, oil-sealed rotary vane pump
Operating instructions GA02341_002_A6
and spare parts list
Part-Nr:
960363V3001
960461V3001
960462V3001
960463V3001
960465V3001
960465V3002
and other variants
Document 300338321/002/A6
Original Operating Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sogevac SV65 BI FC and is the answer not in the manual?

Questions and answers

Summary of Contents for Leybold vacuum Sogevac SV65 BI FC

  • Page 1 Sogevac ® SV40-65 BI FC Single-stage, oil-sealed rotary vane pump Operating instructions GA02341_002_A6 and spare parts list Part-Nr: 960363V3001 960461V3001 960462V3001 960463V3001 960465V3001 960465V3002 and other variants Document 300338321/002/A6 Original Operating Instructions...
  • Page 2: Table Of Contents

    Conditions of use Taking out of use Maintenance Safety Information Maintenance Intervals Oerlikon Leybold Vacuum Service Maintenance Work Troubleshooting Spare parts EC Conformance Declaration Declaration of Contamination of Compressors, Vacuum Pumps and Components GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 3: Important Safety Information

    Depending on the process involved, dangerous substances and oil may escape from the pump. Take the necessary safety precautions ! Disconnect the unit from the power supply before starting any work. Pump must not be operated above 2000 m sea level. GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 4 Design the exhaust line so that no pressure higher than 1,15 bar abs. (0,15 bar rel.) can occur. Operating of the pump without oil or operating with incorrect direction of rotation can destroy the pump. GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 5 Do not allow the ingestion of any objects (screws, welding beads, nuts, washers, pieces of wire, fittings etc.) through the intake port of the pump. Objects falling into the pump can cause severe damage. GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 6: Description

    Some variants are equipped with a frequency converter giving a constant pumping speed independently of the mains frequency and regulating the pump power consumption. At high inlet pressures, the pump speed is decreased. GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 7: Technical Characteristics

    Mains voltage (+/- 10 %) AC ~ Protection - Insulation IP 20 - F Leak rate mbar.I.s <1 x 10 Ambient temperature °C 18 ... 40 See pump nameplate for further data. Given by power & interface connections. GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 8 Mains voltage (+/- 10 %) AC ~ Protection - Insulation IP 20 - F Leak rate mbar.I.s <1 x 10 Ambient temperature °C 18 ... 40 See pump nameplate for further data. Given by power & interface connections. GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 9 Pumping speed (volume flow rate) without gas ballast with gas ballast Courbes de débit sans lest d'air avec lest d'air Courbes de débit sans lest d'air avec lest d'air SV40 BI FC SV65 BI FC GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 10: Accessories

    Lubricants The Sogevac® pumps should be run with vacuum pump oils with a viscosity according to ISO category VG32. Use only the Oerlikon Leybold Vacuum oil indicated on the name plate and pump. In case other oils are used, Oerlikon Leybold Vacuum rejects all responsibility should any trouble occur.
  • Page 11: Transport And Storing

    If the pump has been shelved for over one year, standard maintenance must be done and the oil must be exchanged too before the pump is put in to service once more. We recommend that you contact the service from Oerlikon Leybold Vacuum. GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 12: Installation

    Additional warning note: additional air flow may be needed during ballast, as ■ this increases pump temperature. The inlet pressure must not be above atm. pressure. ■ See also indications on the pump nameplate. 12 GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 13: Electrical Connections

    Following power cables with connection IEC 320 / C19 exist: Reference 140307 l = 1.8 m EUR Schuko plug 140306 l = 1.8 m USA (high V) 140305 l = 1.8 m GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 14 9 : 0 V pin 9 : 24 V Sub-D female Sub-D male For high speed operation, connect 8 and 9. For low speed operation, connect 2 to 4. OPTION 14 GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 15: Oil Filling

    If more than 6 starts per hour are necessary keep the pump running and mount a valve which opens and closes into the intake line. Take note of warning labels on the pump. GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 16: Working In Cycles In / Out

    We recommend strongly to limit starting of the pump to 5 or 6 per hour. If the process need it, we recommend utilization of a pneumatic or electromagnetic valve and to let the pump run continously. 16 GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 17: Switching Off / Shutdown

    Restricted, clogged or blocked exhaust filter or exhaust line Out of tolerance supply voltage Unsuitable, polluted or too old oil Too low oil level Too high ambient temperature Clogged fan hoods or impeded fresh air circulation Etc. GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 18: Maintenance

    Use only OLV spare & consumables. An overhaul at OLV is recommended every 3 years. After maintenance operations, make sure the device is in a safe condition before putting back into operation. 18 GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 19: Oerlikon Leybold Vacuum Service

    A copy of the form has been reproduced at the end of these Operating Instructions: “Declaration of Contamination for Compressors, Vacuum Pumps and Components”. Another suitable form is available from www.oerlikon.com → Oerlikon Leybold Vacuum Systems → Documentation → Download Documents. Attach the form to the equipment or enclose it with the equipment.
  • Page 20 Clean the float chamber of the oil casing. Reassemble in the reverse sequence. 20 GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 21: Troubleshooting

    Clean or repair the oil lines. Exhaust filter / exhaust line is obstructed. Replace the exhaust filter, clean the 5.4-D exhaust line. Pump module is no longer usable. Replace the pump module. 5.4-K GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 22 Contact Oerlikon Leybold Vacuum. * Reference section : This coluum refers to the section in the Operating Instructions that contains the applicable repair information. Never mount used seals. Always mount new seals. GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 23: Spare Parts

    Consummables and main spare parts kits for Sogevac pumps are usually available on stock at Oerlikon Leybold Vacuum’s service centers. The list of these parts is given hereafter and in the spare parts table where the contents of each kit is detailed.
  • Page 24 Spare parts 24 GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 25 FKM - PTFE EK971472900 VACUUM GENERATOR WITH MAN GB SV40BI FC FKM-PTFE EK6700437 VACUUM GENERATOR WITH MAN GB SV65BI FC FKM-PTFE EK971472910 SERVICE KIT SV40BI FC 971427660 SERVICE KIT SV65BI FC 971423440 GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 26: Ec Conformance Declaration

    GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 27: Declaration Of Contamination Of Compressors, Vacuum Pumps And Components

    I / we hereby declare that the information supplied on this form is accurate and sufficient to judge any contamination level. Name of authorised person (block letters):_________________________________ Date________________ Signature of authorised person_____________________ firm stamp GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 28 Notes 28 GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...
  • Page 29 D-50968 Cologne Phone: +49-(0)221-347 0 Fax: +49-(0)221-347 1250 w w w . o e r l i k o n info.vacuum@oerlikon.com l e y b o l d v a c u u GA02341_002_A6 - 12/2013 - © Oerlikon Leybold Vacuum...