SECTION XVI
A.
List of Type Numbers and Their Functions
Type No.
PSUEZGZ
PSU0201
PSFQSll
PSFGSlZ
Description
Switch console and power supply.
Includes one physical PSI channel
(URP/MTP/MSP)
in IOM and one PSFESll
Switch console and power supply.
Same as PSUGZZZ except that no
IOM channel
is included.
Includes
one PSFGSll
Manual switch unit to switch a
device to one of two device
processors, or to select one of
two devices to switch to a
device processor. Does not
include a channel
in
IOM.
Usable with URP and MTP devices
only. Could also be used to switch
a PSI channel
in IOM between 2
device processors - URP, MTP or MSP
Manual switch unit to switch a
device processor to one of two
IOM PSI type physical channels.
Includes one IOM PSI channel.
Usable with URP,
MTP,
MSP only
134
Remarks
Every manual
switch
subsystem must
include only one
switch console,
either PSUGZGD or
PSUZZfll.
Each
console handles up
to 16 switch units
Each console includes
one. May be mixed
with PSF0512 to
maximum of 16 switch
units per console
May be mixed with
PSFGSll to maximum
of 16 switch units
per console