Removal of Electrical Box

3. Removal of Electrical Box
Procedure
Step
1
Remove the 2 screws
of the shield plate.
2
Slide the shield plate
upward to unfasten the
hook on the bottom left,
and then remove the
shield plate.
3
Remove all the screws
of the terminal boards
and of the earth wires.
Disconnect the power
supply wire and the
connection wire.
4
Disconnect the 2 earth
wires.
8
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Hook
Connection wire
Power supply wire
Preparation
Remove the top panel and
the front panel according to
the "Removal of Outer
Shield
plate
Panels".
(R17060)
(R17021)
Earth wire
(R17239)
Earth wire
(R17240)
Si00-875
Points
Removal Procedure