Physical Configuration; Front Panel Controls, Indicators And Test Points; Controls; Indicators - RF Technology Eclipse Series Operation And Maintenance Manual

Table of Contents

Advertisement

7.2 Physical Configuration

7 SPECIFICATIONS
7.2 Physical Configuration
The receiver is designed to fit in a 19 inch rack mounted frame. The installed height is 4RU
(178mm) and the depth 350mm. The receiver is 63.5mm or two eclipse modules wide.

7.3 Front Panel Controls, Indicators and Test Points

7.3.1 Controls

Mute Defeat Switch - toggle (Overrides CTCSS and carrier squelch at the monitor output).
Monitor Speaker Volume - Knob
Line Output Level - Screwdriver adjust multiturn pot
Noise Sq. Setting - Screwdriver adjust multiturn pot
Carrier Sq. Setting - Screwdriver adjust multiturn pot

7.3.2 Indicators

Power On - Green LED
Squelch Open - Yellow LED
Fault Indicator - Flashing Red LED

7.3.3 Test Points

Line Output Level - 6 + Gnd (pin 1)
Receive Signal Strength - 7 + Gnd (pin 1)
Tuning Voltage - 9 + Gnd (pin 1)
Serial data (RS232) - 2/3 + Gnd (pin 1)

7.4 Electrical Specifications

7.4.1 Power Requirements

Operating Voltage - 10.5 to 16Vdc
Current Drain - 500mA Max
Polarity - Negative Ground
___________________________________________________________________________
RF Technology R800
Page 16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eclipse r800Eclipse t800

Table of Contents