Connection to console port
The console port can be used to connect to the CLI (Command Line Interface).
The following steps needs to be taken:
1. Connect the serial diagnostic cable to the console port (use only ABB cable
2. Connect cable to your computer (USB port, if drivers are needed they can be
3. Use a terminal emulator and connect with correct speed and format (115200,
For more information about the CLI, see the NEOS User Manual.
Power connection
4-position
No. 1
No. 2
No. 3
No. 4
NE810 supports redundant power connection. The positive inputs are +DC1 and
+DC2, the negative input for both supplies are –COM. Connect the primary voltage
(e.g. +24 VDC) to the +DC1 pin and return to one of the –COM pins on the power
input.
3BSE080633
3BSE080212R1).
downloaded from our Web page).
8N1) to the assigned port.
Product marking
+DC1
+DC2
-COM
-COM
Section 3 Location of interface ports and LED's
Figure 2. Power Connection
Direction
Input
Input
Input
Input
Description
Supply voltage input DC1
Supply voltage input DC2
Common
Common
13