3

Connections

See Chapter Installation and Maintenance for more information regarding installation.

Connection

For all ABB switches the NC circuits are closed when the guard is closed and the actuator present.
RED
BLUE
(24VDC)
(0VDC)
&
POWER
&
&
RECEIVER 1
RECEIVER 2
ACTUATOR

Cable configurations

Pin configurations

2TLC172249M0201, rev. B
2013-04-10
BLACK (IN)
NC
Circult 1
WHITE (OUT)
NC
YELLOW (IN)
Circuit 2
GREEN (OUT)
ORANGE (IN)
NO
Circult
BROWN (OUT)
RED (24VDC)
BLUE (0VDC)
BLACK (IN)
WHITE (OUT)
GREEN (OUT)
YELLOW (IN)
BROWN (OUT)
ORANGE (IN)
6
External
Supply
24VDC
NC
Circuit 1
NC
Circuit 2
NO
Circuit