Referring Documents; Cable Factory Reset On Ne810; Proceed With Factory Reset - ABB NE810 User Manual

800xa networks
Table of Contents

Advertisement

Referring Documents

Type
User Manual
Network Configuration
Guide

Cable Factory Reset on NE810

It is possible to set the unit to factory default settings by using two straight standard
Ethernet RJ-45 cables.
1. Power off the switch and disconnect all Ethernet cables (copper and fibre).
2. Connect one Ethernet cable between Ethernet ports 3 and 10, and the other
3. Power on the unit.
4. Wait for the unit to start up. Ensure that the ON LED is flashing red. The ON
LED flashing indicates that the unit is now ready to be reset to factory default. You
now have the choice to go ahead with the factory reset, or to skip factory reset and
boot as normal.

Proceed with Factory Reset

Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet
cables. The ON LED will stop flashing. This initiates the factory reset process, and
after approximately 1 minute the unit will restart with factory default settings.
When the switch has booted up, the ON LED will show a green light, and is now
ready to use.
26
Description
ABB NEOS User Manual
System 800xA 6.0 Network
Configuration Guide
between Ethernet ports 6 and 7. The ports need to be connected directly by an
Ethernet cable, i.e., not through a hub or switch. Use a straight cable – not a
cross-over cable – when connecting the ports.
Document Number
3BSE080654 en
3BSE034463-600 en
3BSE080633

Advertisement

Table of Contents
loading

Table of Contents