Instructions for the installer

7. ADAPTATION TO DIFFERENT TYPES OF GAS

The appliance is preset for natural gas G20 (2H) at a pressure of 20 mbar. In the case of operation with
other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas
taps. To change the nozzles, proceed as described below.

7.1 Replacing nozzles

1 Extract the grid and remove all the caps and flame-spreader crowns;
2 Unscrew the burner nozzles with a 7 mm socket wrench;
3 Replace the burner nozzles according to the type of gas to be used (see point "8.1 Burner, nozzle
and gas consumption characteristics").
4 Replace the burners in the correct position.
41