Adaptation To Different Types Of Gas - Smeg Gas Cooktop CIR60XS Instruction Manual

Smeg gas cooktop instruction manual
Hide thumbs Also See for Gas Cooktop CIR60XS:
Table of Contents

Advertisement

Instructions for the installer

6. ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, detach the
appliance from the electrical socket.
The hob has been inspected for NG natural gas at a pressure of 1.0
kPa. For functioning with other types of gas the nozzles must be replaced
and the primary air adjusted.
To replace the nozzles and regulate the burners, you have to remove the
top as described in the following paragraph.
6.1 Removing the hob
1.
Remove all the knobs, the grids, the burner caps and the flame-caps;
2.
remove the screws and the nuts A that secure the burner supports;
3.
remove plates B;
4.
lift the hob from its seat;
5.
replace the burner nozzles in accordance with the reference gas
chart;
6.
regulate the primary air as described in paragraph "6.2 Regulation
for LPG".
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cir60xSa60wSa60xSar60wSar60xCir60xs3

Table of Contents