Inverter Settings
7-2-4

Setting the Multi-function Inputs (n36 to n39)

n36
Multi-function input 1 (S2)
Setting
2 to 8, 10 to 22
range
n37
Multi-function input 2 (S3)
Setting
0, 2 to 8, 10 to 22
range
n38
Multi-function input 3 (S4)
Setting
2 to 8, 10 to 22
range
n39
Multi-function input 4 (S5)
Setting
2 to 8, 10 to 22, 34, 35
range
• In addition to the methods described above, the RUN command and
frequency reference can be input through RS-422A/485 communications
by setting the value 18 in any one of the parameters from n36 to n39
(multi-function input).
• Subsequently, the following operations are selectable in remote mode.
None of these parameters, however, can be changed while the operation
command is being input.
When the function-set input terminal is OFF, the RUN command will be
executed according to the setting in n02 (operation command selection)
and the frequency reference will be executed according to the setting in
n03 (frequency reference selection).
When the function-set input terminal is ON, the Inverter will operate
according to the RUN command and frequency reference through RS-
422A/485 communications.
Register
0124 Hex
Unit of
1
setting
Register
0125 Hex
Unit of
1
setting
Register
0126 Hex
Unit of
1
setting
Register
0127 Hex
Unit of
1
setting
Changes during
No
operation
Default setting
2
Changes during
No
operation
Default setting
5
Changes during
No
operation
Default setting
3
Changes during
No
operation
Default setting
6
Chapter 7-2
97