Down/Up-Fast/Slow-Max/Min-Datarate - SMC Networks TigerAccess SMC7816M Management Manual

6-band vdsl2 switch
Hide thumbs Also See for TigerAccess SMC7816M:
Table of Contents

Advertisement

Related Commands
lre interleave-max-delay (29-25)

down/up-fast/slow-max/min-datarate

These commands set the maximum/minimum data rate on a fast/slow
downstream/upstream channel. Use the no form to restore the default
settings to the profile.
Syntax
{down|up}-{fast|slow}-{max|min}-datarate value
no {down|up}-{fast|slow}-{max|min}-datarate
• down – Downstream bands.
• up – Upstream bands.
• slow – Slow (interleaved) channel.
• fast – Fast channel.
• max – Maximum channel data rate.
• min – Minimum channel data rate.
• value – The data rate. (Range: 1-200,000 kbps)
Default Setting
Maximum data rate: 200,000 kbps
Minimum data rate: 64 kbps
Command Mode
VDSL Line Profile
Command Usage
The command sets the minimum and maximum data rates supported
by each upstream and downstream band. Bounding data rates should
be set for both fast and slow channels if operation may sometimes
disable or enable interleaving.