Note:
The optical components (transmitter and receiver) on a fiber optic link must be of the same
type.
Plastic optical fiber (POF) cables can be used with both 5 MBd and 10 MBd optical
components. 10 MBd components also enable the use of Hard Clad Silica (HCS®) cables,
which allow longer connection distances thanks to their lower attenuation. HCS® cables
cannot be used with 5 MBd optical components.
The maximum lengths of fiber optic links for POF and HCS® cables are 20 and 200 meters
respectively.

Ambient conditions

The unit is to be used in a heated indoor controlled environment.
Altitude above sea level
Air temperature
Relative humidity
Contamination
Chemical gases
Solid particles
Operation installed for
stationary use
0 ... 2000 m
(0 ... 6561.7 ft) no derat-
ing.
For altitudes over 2000 m
(6561.7 ft), contact ABB.
0 ... +55 °C
(+32 ... +131 °F), no con-
densation allowed.
Maximum 95%, no con-
densation allowed
No condensation allowed. Maximum allowed relative humidity is 60% in the presence
of corrosive gases.
IEC/EN 60721-3-3:2002:
Classification of environ-
mental conditions - Part 3-
3: Classification of groups
of environmental paramet-
ers and their severities -
Stationary use of weather
protected locations
Class 3C2
Class 3S1
No conductive dust al-
lowed.
Storage in protective
package
-
-40 ... +70 °C
(-40 ... +158 °F)
Maximum 95%, no con-
densation allowed
IEC 60721-3-1
Class 1C2
Class 1S3 (packing must
support this, otherwise
1S2)
Technical data 79
Transportation in protect-
ive package
-
-40 ... +70 °C
(-40 ... +158 °F)
Maximum 95%, no con-
densation allowed
IEC 60721-3-2
Class 2C2
Class 2S2

Advertisement