Apparatens märkskylt (FM)
SITRANS Probe LR
7MLxxxx-xxxxx-xxxx
Serial No: GYZ / S1034567
Encl.: NEMA / TYPE 4X, 6, IP67, IP68
Amb.Temp.: – 40 °C to 80 °C
Power Rating: 24V
Nom., 30 V
Siemens Milltronics Process Instruments, Peterborough
Assembled in Canada with domestic and imported parts
FM Egensäker anslutning ritning nummer A5E01003040 kan laddas ner från produktsidan på
vår webbsida: www.siemens.com/probelr. Gå till Support > Installation Drawings
(Installationsritningar) > Level Measurement (Nivåmätning) > Continuous – Radar
(Kontinuerlig – Radar).
Apparatens märkskylt (CSA)
SITRANS Probe LR
7MLxxxx-xxxxx-xxxx
Serial No: GYZ / A1034567
Encl.: NEMA / TYPE 4X, 6, IP67, IP68
Amb.Temp.: – 40 °C to 80 °C
Power Rating: 24V
Nom., 30 V
Siemens Milltronics Process Instruments, Peterborough
Assembled in Canada with domestic and imported parts
CSA Egensäker anslutning ritning nummer A5E01003039 kan laddas ner från produktsidan på
vår webbsida: www.siemens.com/probelr. Gå till Support > Installation Drawings
(Installationsritningar) > Level Measurement (Nivåmätning) > Continuous – Radar
(Kontinuerlig – Radar).
• För kabeldragningskrav: följ lokala bestämmelser.
• Godkända dammtäta och vattentäta kanaltätningar krävs utomhus typ 4X / NEMA 4X,
typ 6 / NEMA 6, IP67, IP68 platser.
Instruktioner som gäller installation på riskabla platser (Referens: Europeiska ATEX-
• Se
direktivet 94/9/EG, Bilaga II, 1/0/6)
• För effektbehov se
2. Icke antändlig kabeldragning (endast FM/USA)
SITRANS Probe LR
7MLxxxx-xxxxx-xxxx
Serial No: GYZ / S1034567
Encl.: NEMA / TYPE 4X, 6, IP67, IP68
Amb.Temp.: – 40 °C to 80 °C
Power Rating: 24V
Nom., 30 V
Siemens Milltronics Process Instruments, Peterborough
Assembled in Canada with domestic and imported parts
FM Klass 1, Div 2 anslutningsritning nummer 23650537 kan laddas ner från produktsidan på
vår webbsida: www.siemens.com/probelr. Gå till Support > Installation Drawings
(Installationsritningar) > Level Measurement (Nivåmätning) > Continuous – Radar
(Kontinuerlig – Radar).
• För effektbehov se
A5E32106153
6.3 GHz
Max., 4 - 20mA
HART
6.3 GHz
Max., 4 - 20mA
HART
på sida 8.
Loop power
på sida 4 Bilaga A.
6.3GHz
Max., 4 - 20mA
HART
Loop power
på sida 4 Bilaga A.
SITRANS Probe LR – SNABBSTARTSMANUAL
Class I, Div 1, Group A, B, C, D
Vmax = 30 V
Class II, Div 1, Group E, F, G
Imax = 120 mA
Class III
Pmax = 0.8 W
Temp. Code: T4
FM per drawing A5E01003040
FCC ID: NJA-LR200
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions 1)This device may not cause harmful interference and
2)This device must accept any interference received, including interference that
may cause undesired operation
WARNING: Possible Static Hazard, Do Not Rub Or Clean On Site.
Class I, Div 1, Group A, B, C, D
Class II, Div 1, Group E, F, G
Class III
Temp. Code: T4
CSA per drawing A5E01003039
IC: 267P - LR200
WARNING: Possible Static Hazard, Do Not Rub Or Clean On Site.
FCC : NJA–LR200
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions
1)This device may not cause harmful interference and
Class I,Div.2,
2)This device must accept any interference received, including
Group A,B,C,D
interference that may cause undesired operation
Temp.Code:T5
Ci = 15 nF
Li = 0.1 mH
Vmax = 30 V
Imax = 120 mA
Pmax = 0.8 W
Ci = 15 nF
Li = 0.1 mH
159134