6. Notes

Read the following notes thoroughly before using the BBU.

6-1. Notes on Installation

Do not put the BBU on a metallic plate, including the chassis of the server.
Do not hold the BBU with wet hands.
If you do not follow these directions, the battery may be short-circuited.

6-2. Notes on Operation

The life of the battery pack used for the BBU is about 2 years, which may vary a little depending on
the environment of use and the environmental conditions. Replace the battery pack with a new one two
years after the installation. For the replacement, contact your service representative.
To manage properly the BBU states, install the "MegaRAID Storage Manager" RAID Controller
Management Utility. The MegaRAID Storage Manager allows you to detect errors and check the BBU
states.
The following alert may be logged when you restart the system immediately after charging the BBU,
but you can ignore it. If you continue to charge the BBU, the alert will no longer be logged.
- When the battery is charging
Your battery is either charging, bad or missing,and you have VDs configured
for write-back mode. Because the battery is not currently usable,these VDs
will actually run in write-through mode until the battery is fully charged
or replaced if it is bad or missing.
The following VDs are affected :XX
Press any key to continue.
- When the battery is missing
The battery hardware is missing or malfunctioning, or the battery is
Unplugged, or the battery could be fully discharged. If you continue to
boot the system, the battery-backed cache will not function.
If battery is connected and has been allowed to charge for 30 minutes
and this message continues to appear, then contact technical support for
assistance.
Press 'D' to disable this warning (if your controller does not have a battery).