Connecting Vented Stove To The Flue - HOSSEVEN HDU-5 Instruction Manual

Fireplace - natural gas - lpg stove
Table of Contents

Advertisement

combustion can be observed due to special thermal shock resistant glass, which is made from
ceramic material. The heated surfaces are covered with high quality enamel.

5.1 CONNECTING VENTED STOVE TO THE FLUE

Make sure that flue, which will be connected to stove, is clean and well draught. Connect
your stove to shunt (indirect) or free-standing flue. Do not mount flue pipe to the flue of poor
quality or do not mount as directly remove outside.
Connect your stove to the flue by using pipe of 13 by means of adaptor (8-13)
Connect stove pipe to the flue in an upward slope of 3%
Adjust the part of pipe inside of flue as not to reduce flue draught
Ensure sealing by closing the part of pipe inside of flue with non-combustible material
(plaster, etc)
Figure 5: Flue connection
5.2 REPLACEMENT OF VENTED STOVE
Remove stove from its packaging and place it on a flat surface. Place stove to the any edge
near flue and gas valve as free air flow will be available. Make sure you have at least 20 cm
space between the stove and the wall. Figure 6
Walls and floors must be temperature resistant for at least 8 C If necessary, take measures
by replacing marble under and behind of stove. 100 cm2 air vents must be installed to the fixed
part of outer window of the room, where stove is located.
8