The wall, where device connection will be done, must be fireproof and resistant to minimum
270C. The outlet in the external wall cannot be opened to everywhere. Take measures by
replacing protective marble, plates, etc. under your stove. Do not connect hermetic kit to the
flue.
Hermetic kit connection must be at least 60 cm in each direction of flammable surface
coating and vertical distance must be at least 1.5 m to the roof eaves. In the area shown in the
figure; the distance of location, where hermetic kit holes are connected from wall, must be as
shown in the figure.
Figure 1: Stove mounting distances
WARNING: The specified fire protection distance as shown in the İnstruction .It must be
strictly kept and checked. The installation must comply for valid standards. Disregard of
these instruction can result in death ,injury or property damage.
WARNING: The installation of appliance must be only executed by authorized persons.
Quarantee of appliance can be ensured only in this case.
WARNING: Before every maintanance ,the appliance must be turned off electrical and gas
Supply.
Disregard of these instruction can result in death ,injury or property damage