Download Print this page

Electrical Box / Pcbs / Swing Motor - Daikin FT15LV14 Service Manual

Removal procedure, 1.5/2.0/2.5/3.5 kw class, indoor unit, non-inverter, wall mounted type, cooling only

Advertisement

Si041265EC

4. Electrical Box / PCBs / Swing Motor

Warning
Step
1. Remove the electrical
box.
1
Remove the 4 screws
and disconnect the
connecting wires.
2
Remove the screw, and
then the wire fixture.
3
Disconnect the
connectors.
4
Pull out the indoor heat
exchanger thermistor.
5
Remove the screw on
the terminal board.
6
Remove the screw, and
then the electrical box.
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Wire fixture
Connecting
wire
Indoor heat
exchanger thermistor
Electrical Box / PCBs / Swing Motor
(R18503)
[S1] / [CN_FAN]
[S7] / [CN_FANFB]
[S6] / [CN_STP]
(R21155)
Terminal
board
(R18505)
Hook
Points
[S1] / [CN_FAN]: fan motor
[S7] / [CN_FANFB]: fan motor
[S6] / [CN_STP]: swing motor
When reassembling the
electrical box, make sure the
hook on the back is securely
fastened.
(R21156)
5