Removal procedure, 1.5/2.0/2.5/3.5 kw class, indoor unit, non-inverter, wall mounted type, cooling only

Advertisement

Indoor Heat Exchanger

5. Indoor Heat Exchanger
Warning
Caution
Step
1
Remove the 2 screws
which fix the indoor
heat exchanger to the
installation plate.
2
Disconnect the drain
hose.
3
Disconnect the gas
piping and the liquid
piping.
4
Remove the indoor unit
from the installation
plate.
5
Unfasten the hook and
remove the piping
fixture on the back.
8
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
In pump-down work, be sure to stop the compressor before disconnecting the
refrigerant pipe. If the refrigerant pipe is disconnected with the compressor operating
and the stop valve open, air may be sucked in and may generate an over-pressure in
refrigeration cycle, thus resulting in pipe rupture or accidental injury.
When removing or reinstalling the indoor heat exchanger, be sure to wear gloves or
wrap the indoor heat exchanger with cloths. (You may be injured by the fins.)
Be sure to conduct pump down operation before disassembling the refrigerant pipe.
If the refrigerant leaks, repair the spot of leaking, then collect all refrigerant from the
unit. After conducting vacuum drying, recharge proper amount of refrigerant.
From the viewpoint of global environmental protection, make sure to use a vacuum
pump for air purging.
Procedure
Piping fixture
Place a plastic sheet around
the drain pan to prevent
wetting the floor with
remaining drain.
If the drain hose is
embedded in the wall,
disconnect the drain hose
beforehand.
Drain hose
(R18764)
Hold the indoor unit up with a
piece of wood.
Carry out the removal works
with 2 wrenches.
When the pipings are
disconnected, protect the
openings of both the pipes
and the indoor unit from
moisture intrusion.
(R2545)
(R18760)
Si041265EC