Check the actual output.
Normal
Should be maintenance monitor
#51 (FF + FB No.) x 50% < #52 (Output) data.
Check whether the Thermistor-Cold Water and Thermistor-Hot Water are normal.
Normal
Disconnect electrical power,
(pass through the water to the Unit.)
e, and then reconnect electrical power.
Check the maintenance monitor.
The difference between # 30 (Cold Water ) and # 31
(Hot Water) should be within ±5 ˚ F.
Check the thermistor resistance.
Normal
1
CN63 White 4 - Black 2 (Cold Wa ter)
2
CN63 White 1 - Black 2 (Hot Wa ter)
Refer to the thermistor temperature
characteristics below.
Circuit Board
14
13
14
13
12
BL
12
BL
11
W
10
R
9
Y
11
W
8
7
6
BK
10
R
5
BK
4
W
3
W
2
BK
9
Y
1
W
<CN63>
8
<CN135>
7
<CN78>
6
BK
2
1
1
BL
2
5
BK
3
BL
4
R
5
W
4
W
6
O
7
GY
8
BK
<CN10>
3
W
9
10
W
11
BL
2
BK
12
6
BK
13
W
14
5
R
1
W
15
BL
4
3
2
W
1
W
<CN42>
<CN63>
51
Abnormal
Abnormal
Abnormal
Check for improper connection of wiring,
connectors, etc., then replace the thermistor.
When measuring the resistance,
disconnect the connector and check
the male side.
12
W
11
Y
10
O
9
R
8
7
Main
6
BK
5
V
Circuit
4
G
3
O
Board
2
Y
1
W
<CN59>
1
2
1 2 3
3
4 3 2 1
4
BL
4
R
3
BL
BR Y BL R
5
O
2
BL
6
Y
<CN27>
1
R
7
W
<CN142>
Po wer
<CN104>
Circuit
3
R
Board
2
BL
1
G
<CN101>
<CN89B>
3
2
1
<CN75>
3
2
1
BL/W
R/R
G
<CN102>
<CN89A>
Replace the Circuit Board set.
* It is not necessary to replace the
Displ ay Window Circuit Board.
Check for clogged w
then replace the Water Flow Sensor.
Replace the Circuit Board set.
* It is not necessary to replace the
Displ ay Window Circuit Board.
Displ ay Window
Fuse
Circuit Board
Data
Display
W
3
1
W
BK 4
2
BK
<CN92>
Dip Switch
1 2 3 4
R BL BL BL
<CN142>
s,

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nr662-odNrc711-odNrc661-dvNrc661-odNrc711-dv

Table of Contents