Freeze Prevention Control; Freeze Prevention Heater - Noritz NR501-OD Service Manual

Hide thumbs Also See for NR501-OD:
Table of Contents

Advertisement

Freeze Prevention Control

<NR501-OD, NR662-OD>
301,302 / 30
Heaters turn ON

Freeze prevention heater

7
Thermistor-Air
normal
Thermistor-Air
less than 37 ゚F (3
゚C
)
YES
Thermistor-Air
less than 28 ゚F (-2
)
゚C
YES
Heaters turn ON
Thermistor-Air
more than 14 ゚F (-10
)
゚C
YES
Has 50 min passed
YES
Heaters turn OFF
Thermistor-Air
more than 14 ゚F (-10
゚C
)
YES
Has 5 min passed
YES
NO
NO
C
Heaters turn ON
NO
NO
Thermistor-Air
more than 14 ゚F (-10
NO
Has 20 min passed
Heaters turn OFF
NO
Thermistor-Air
C
more than 14 ゚F (-10
NO
Has 15 min passed
21
゚C
)
YES
NO
YES
NO
C
゚C
)
YES
NO
YES