The Fan Does Not Operate When The Hot Water Fixture Is Opened - Noritz NR501-OD Service Manual

Hide thumbs Also See for NR501-OD:
Table of Contents

Advertisement

1-2. The fan does not operate when the hot water fixture is opened.
Check whether the Water Flow Sensor is normal.
Normal
Check the Display Window ( 1).
Open the hot water xture fully.
Co n rm 0.5 gal/min. or more by
using maintenanc e monitor #14.
When not using the maintenance
monitor:
CN 63
Betwe en Red 10 – Blue 12
DC 14 – 16V
or
CN 63
Be tween Y ellow 9 (+) – Blu e 12 (-)
over 17 .8 Hz
Check the voltage between Red 10 and Blue12.
Check the pulses between Yellow 9 and Blue12.
Check whether the Thermistor-Cold Water Detection is too high.
(Check the Inlet Water temperature.)
Normal
Abnormal
*1 and *2 to the right
*1 << How to check >>
do not apply in this
case.
*2
A
1 Check the Display Window.
When 1 minute passes after the water flow
is detected, the outside edge of the three
digit display will rotate in a circular pattern.
Abnormal
Circuit Board
14
13
12
BL
11
W
10
R
14
9
Y
8
13
7
6
BK
12
BL
5
BK
4
W
11
W
3
W
2
BK
10
R
1
W
<CN63>
1 2 3
9
Y
<CN135>
8
7
<CN78>
6
BK
2
1
5
BK
1
BL
2
3
BL
4
W
4
R
5
W
6
3
W
O
7
GY
8
BK
<CN10>
2
BK
9
10
W
1
W
11
BL
12
6
BK
13
W
5
R
14
<CN63>
15
BL
4
3
2
W
1
W
<CN42>
Abnormal
Normal
Abnormal
.
1
The Unit will not run to prevent scalding hot water temperature.
[001] : Water inlet temperature is too high
If possible decrease water inlet temperature
[002] : "Predicted water outlet temperature*
[004] : Inlet and Outlet temperature are reversed
Check the pipes and re-install it correctly
If "Predicted water outlet temperature" is too high, the Unit will not run to prevent scalding hot
water temperature.
Set Temperature (°F)
Less than 1 25°F
125°F or more
26.1
>
K
Total Flow Rate (gal/min)
K : Predicted outlet water temperature
26.1 : Coe c ient for NRC711-DV and NRC 711-OD
33
12
W
11
Y
10
O
9
R
8
7
Main
6
BK
5
V
Circuit
4
G
3
O
Board
2
Y
1
W
<CN59>
1
2
3
4 3 2 1
4
BL
4
R
3
BL
BR Y BL R
5
O
2
BL
6
Y
<CN27>
1
R
7
W
<CN142>
Power
<CN104>
Circuit
3
R
Board
2
BL
1
G
<CN101>
<CN89B>
3
2
1
<CN75>
3
2
1
BL/W
R/R
G
<CN89A>
<CN102>
Check for improper connection of wiring.
Replace the W ater Flow Sensor.
" is too high
2
K ( Predicted water temperature)
136°F
Set Temperature
+ 18°F
+ Thermistor - Cold Water Detection Temperature (°F)
Check whether a solar water heater is directly coupled or
whether the hot w
Display Window
Fuse
Circuit Board
Data
Display
W
3
1
W
BK 4
2
BK
<CN92>
Dip Switch
1 2 3 4
R BL BL BL
<CN142>
Replace the Circuit Board
* It is not necessary to replace the
Display Window Circuit Board.
Replace the Circuit Board
* It is not necessary to replace the
Display Window Circuit Board.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nr662-odNrc711-odNrc661-dvNrc661-odNrc711-dv

Table of Contents