Repair instructions
7.12 Dismantling the main switch
1
Dismantle the main cables.
See Chapter 7.8.
2
Loosen contact (A) from pin B+ on the main switch.
NB! Do not pull the wires.
See figure 35
3
Take loose the connector (B) using a small screw-
driver to carefully free the heels (C) on each end of
the connector and main switch from each other.
NOTE!
Do not pull the wires. Take special care to
avoid damaging the contact (B).
See figure 36
Cleaning and inspection
Clean and inspect the main switch and cables.
They must always be replaced with new ones if
cracked or showing signs of other defects.
Always use original spare parts.
See figure 37
WARNING!
The "button" on the main switch
may only be tested when it is as-
sembled in the machine!
32
– English
A
Fig 35
C
C
Fig 36
Fig 37
B