7
Place the blow pipe and motor housing in the chassis.
Make sure the rubber pads are positioned correctly.
See figure 22
NOTE!
Ensure cables, etc., are positioned correctly
to avoid pinching.
8
Couple connector (A) to the control unit. Take care
not to damage the connector (B) with cables.
Couple connector (C) to the contact spring.
NB! Do not pull the wires.
See figure 23
Fig 22
Fig 23
Repair instructions
A
B
C
27