Technical data

Note
For an AC input voltage, the technical data is applicable for rated input voltage, rated load
and +25° C ambient temperature (if nothing else is specified).
6.1

Input

Input
U
Rated voltage
e rated / for
AC
Voltage range / for AC
Rated voltage Ue rated / for
DC
Voltage range / for DC
Wide-range input
Overvoltage strength
Power failure buffering
at Ia rated, min.
Power failure buffering
Rated line frequency
Line frequency range
Input current / at rated value
of input voltage 100 V/rated
value
Input current / at rated value
of input voltage 230 V
Inrush current limiting
(+ 25 °C), max.
I²t, max.
Integrated input fuse
Protection in the line feeder
cable (IEC 898)
SITOP PSU100C
Operating Instructions, 06.2013, C98130-A7599-A1-2-7629
6EP1321-5BA00
6EP1322-5BA10
(12 V/2 A)
(12 V/6.5 A)
1-phase AC or DC
100...230 V
85...264 V
120...230 V
110...300 V
Yes
2.3 x Ue rated, 1.3 ms
20 ms
at Ue = 230 V
50/60 Hz
47...63 Hz
0.63 A
1.6 A
0.31 A
0.8 A
33 A
31 A
1.2 A²·s
3 A²·s
Internal
Recommended miniature circuit-breaker: Characteristic B from 16 A or characteristic C
from 10 A
6EP1331-5BA00
6EP1331-5BA10
(24 V/0.6 A)
(24 V/1.3 A)
0.28 A
0.63 A
0.18 A
0.31 A
28 A
34 A
0.7 A²·s
1.2 A²·s