Ambient Conditions; Transport And Storage Conditions - Siemens SIMATIC IFP2200 INOX MT ETH Compact Operating Instructions

Hmi devices
Hide thumbs Also See for SIMATIC IFP2200 INOX MT ETH:
Table of Contents

Advertisement

Technical specifications

5.5 Ambient conditions

DC power supply
Rated voltage
Power consumption
* Electrical isolation within the safety extra-low voltage circuit
The power loss generally corresponds to the specified value for power consumption.
1
Material
Component
Front frame
Front glass
Mounting gasket
5.5
Ambient conditions
5.5.1

Transport and storage conditions

Proper transport and storage, installation and assembly as well as careful operation and
maintenance are prerequisites for trouble-free and safe operation of the device.
Non-compliance with these regulations shall render the device warranty void.
Mechanical transport and storage conditions
The following information is for a device that is transported and stored in its original
packaging.
The device meets the requirements according to IEC 60721-3-2 Class 2M2 with the following
amendments and limitations:
Type of condition
Free fall
Vibration according to IEC 60068-2-6
Shock according to IEC 60068-2-27
36
1
Material
Stainless steel, material number 1.4301, V2A
Float glass, toughened; tempered safety glass (ESG)
Shock-resistant according to EN62262 IK08 (5J, ball drop test)
Anti-glare (gloss 85) through etching
No surface coating
Injury-avoidance (occupational safety): Defined fracture pattern when
broken: Breaks into glass particles (no sharp-edged splinters)
EPDM, 70 Shore A, black
IFP2200 MT ETH
24 V DC, electrically isolated *
40 W
Permitted range
≤ 1 m
5 .. 8.4 Hz, deflection 3.5 mm
8.4 ... 500 Hz, acceleration 1 g
250 m/s
, 6 ms, 1000 shocks
2
Compact Operating Instructions, 03/2018, A5E42185570-AA
IFP2200 INOX MT ETH

Advertisement

Table of Contents
loading

Table of Contents