ASSEMBLY INSTRUCTIONS

15. To secure the unit, please use three nails M8 x 100
(not included) to nail the unit to the ground.
16. Connect the regulator and hose assembly (RR) to the
propane cylinder (not included). The propane gas and
cylinder are sold separately.
CONNECTING GAS CYLINDER
Use only 20-pound cylinders (approximately 18 ¼ inches high
and 12 ¼ inches in diameter) equipped with a cylinder connection
device compatible with the connection for outdoor cooking
appliances. The gas cylinder should not be dropped or handled
roughly!
Minimum Gas Supply Pressure: 25 psi / 175 kPa
Maximum Gas Supply Pressure Bottle pressure
Outlet prssure setting of regulator is 11.0 in. W.C / 2.74 kPa -LPG.
Storage of an appliance indoors is permissible only if the cylinder
is disconnected and removed from the appliance. A cylinder must
be stored outoors in a well-ventilated area out of the reach of
children.
A disconnected cylinder must have dust caps tightly installed and
must not be stored in a building, garage or any other enclosed
area.
The minimum hourly of 17000Btu/H / 4.98 KW is required input
rating for a heater for automatic operation at ratings less than full
input rating.
The pressure regulator and hose assembly supplied with the
appliance must be used. The installation must conform with local
codes, or in the absence of local codes, with national fuel gas
code, ANS Z223.1/NFPA54, natural gas and propane Installation
Code, CSA B149.1, or propane storage and handling code,
B149.2.