Pressure Relief Procedure
WARNING
The accessory remote pressure pot remains
pressurized until pressure is manually relieved.
To reduce the risk of serious injury from pressur-
ized fluid or accidental spray from gun, always
relieve pressure in the pressure pot before loos-
ening or removing the cover, if the fluid nozzle
clogs and before cleaning, checking or servicing
equipment..
Relieve remote pressure pot as follows: F
1
Turn off air supply to pressure pot.
2
2-1/2 gallon remote pressure pot: Pull pressure
relief valve ring (206c) until pressure is completely
relieved.
2 quart remote pressure pot: Turn pressure relief
knob. Wait until pressure is completely relieved
before removing cover. Close knob.
F
. 13
IG
10
. 13.
IG
133
2 quart
ti7062a
Fill Cup or Remote Pressure Pot
Spray Gun Cup
WARNING
The spray gun cup is pressurized by the gun's air
supply. To reduce the risk of serious injury from
pressurized fluid or accidental spray from gun,
always turn off the air supply to the gun before
removing the spray gun cup.
Fill cup 3/4 full to keep air pressure tube clean. Install
cover. Latch the under-cup cover (H) to secure it to cup.
F
. 14.
IG
Note: Strainer may be removed for high viscosity appli-
cations which may plug strainer.
H
ti5158a
F
. 14
IG