  • Page 1 HI99300 • HI99301 Waterproof EC, TDS and Temperature Meter with Advanced Features...
  • Page 2 All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895, USA.
  • Page 3: Table Of Contents

    Table of Contents ............Preliminary Examination ........... General Description and Intended Use ......Main Features ............Specifications ............Display Description ........... Operational Guide ............ Meter Setup ............. Battery Replacement ..........Accessories ............... Probe Maintenance ........... Certification .............. Recommendations for Users ........Warranty ..............
  • Page 4: Preliminary Examination

    DIN connector and 1m (3.3’) cable • HI70031 1413 μS/cm and HI70032 1382 ppm 1 sachet each for HI99300 • HI70030 12880 μS/cm and HI70038 6.44 ppt 1 sachet each for HI99301 • 100 mL beaker (1 pcs.) •...
  • Page 5: General Description And Intended Use

    HI99300 HI99301 are conductivity, total dissolved solids and temperature measurement encountered in man‑ ufacturing and environmental testing protocols. To increase precision, two models are available, with dif‑ ferent conductivity ranges, for applications from purified to brackish waters. All operations, settings and temperature scale selections, are made through only 2 buttons.
  • Page 6: Main Features

    Main features: • Simultaneous EC/TDS and temperature measurements on a large LCD display; • Selectable temperature unit. • HI763063 dedicated EC/TDS/temperature probe • Probe quick connect system • Battery life indication and low battery detection • Auto‑off function • Keystroke confirmation tone •...
  • Page 7: Specifications

    HI99300 HI99301 0 to 3999 μS/ 0.00 to 20.00 mS/ Range 0 to 2000 ppm 0.00 to 10.00 ppt Temp. ‑5.0 to 105.0 °C / 23.0 to 221.0 °F 1 μS/cm 0.01 mS/cm Resolu‑ 1 ppm (mg/L) 0.01 ppt (g/L) tion Temp.
  • Page 8: Display Description

    1 Automatic Temperature Compensation indicator 2 Stability indicator 3 Battery percentage 4 TDS conversion factor 5 Low battery indicator 6 Measurement unit 7 Primary LCD 8 Temperature unit 9 Secondary LCD 10 Meter modes indicator 11 EC calibration tag...
  • Page 9: Operational Guide

    Each meter is supplied with batteries. Before using the meter for the first time, open the battery compartment and insert batteries, observing the polarity (see “Battery Replacement“). TO CONNECT THE ELECTRODE With the meter turned off, connect the HI763063 probe to the DIN socket on the bottom of the meter by aligning the pins and pushing in the plug firmly.
  • Page 10 Battery life check up → → Sensor Measurement check mode → Note: The meter detects the presence and the type of the probe at its input. - If the probe is not connected the message “NO” ”PROBE“ appears alternatively on the secondary LCD. - If the probe is not compatible “WRONG”...
  • Page 11 TO ENTER CALIBRATION MODE Press and hold the button until ”POWER” and is replaced by “STD“, tag if standard calibration is selected from setup menu. Release the button. TO ENTER SETUP MODE Press and hold button until “STD“ and tag is re‑ placed by “SETUP“...
  • Page 12 Select calibration “STD“ . The meter enters the calibration mode and “μS 1.41 USE” (HI99300) or “mS 12.88 USE“ (HI99301) is displayed with tag blinking. Immerse the probe in calibration solution. If the standard value is recognized “REC“ is displayed then “WAIT“...
  • Page 13: Meter Setup

    SETUP MODE Setup mode allows the selection of the Temperature unit, Auto‑off, Beep, temperature compensation factor for EC and TDS conversion factor. To enter Setup mode press and hold button until “STD“ and tag is replaced by “SETUP“ and tag. Release the button. •...
  • Page 14: Battery Replacement

    BATTERY REPLACEMENT When the remaining battery life is less than 10% the battery tag blinks on the display to warn the user. Battery Error Prevention System (BEPS) If the battery is too weak (“0%”) the display shows “bAtt“, “DEAD“ for few seconds then the meter power off. Immediately replace the batteries with new ones.
  • Page 15: Accessories

    Conductivity probe/total dissolved solids HI763063 with built‑in temperature sensor, DIN connector and 1 m (3.3’) cable HI7030M 12880 μS/cm solution, 230 mL bottle HI7031M 1413 μS/cm solution, 230 mL bottle 1382 ppm (mg/L) solution, 230 HI7032M mL bottle HI70038M 6.44 ppt (g/L) solution, 230 mL HI70442M 1500 ppm (mg/L) solution, 230 mL HI710028...
  • Page 16 Code and serial number on the other side Quick connector with Rubber protection, and 1 meter cable Temperature sensor EC/TDS sensor...
  • Page 17: Probe Maintenance

    PREPARATION • Remove the protective cap. Rinse with water. STORAGE • Replace the protective cap. Note: NEVER STORE THE ELECTRODE IN DISTILLED WATER. CLEANING PROCEDURE • Soak in Hanna HI7061 general cleaning solution or for approximately 20 minutes. Rinse well and calibrate before using.
  • Page 18: Certification

    All Hanna Instruments conform to the CE European Directives. RoHS compliant Disposal of Electrical & Electronic Equipment. The product should not be treated as household waste. Instead hand it over to the appropriate collection point for the recycling of electrical and electronic equipment which will conserve natural resources.
  • Page 19: Recommendations For Users

    Technical Service department and then send it with shipping costs prepaid. When shipping any meter, make sure it is properly packed for complete protection. Hanna Instruments reserves the right to modify the design, construction or appearance of its products without advance notice.
  • Page 20 World Headquarters Hanna Instruments Inc. Highland Industrial Park 584 Park East Drive Woonsocket, RI 02895 USA www.hannainst.com Local Office Hanna Instruments Inc. 270 George Washington Highway Smithfield, RI 02917 Phone: 800.426.6287 Fax: 401.765.7575 e‑mail: tech@hannainst.com MAN99300 Printed in ROMANIA...