Main Zone - Daikin Altherma EPGA14DAV3 Installer's Reference Manual

Low temperature split
Hide thumbs Also See for Altherma EPGA14DAV3:
Table of Contents

Advertisement

NOTICE
When adjusting the room temperature ranges, all desired
room temperatures are also adjusted to guarantee they are
between the limits.
#
Code
[1.5.1]
[3-07]
Heating minimum
[1.5.2]
[3-06]
Heating maximum
[1.5.3]
[3-09]
Cooling minimum
[1.5.4]
[3-08]
Cooling maximum
Room sensor offset
ONLY applicable in case of room thermostat control. You can
calibrate the (external) room temperature sensor. It is possible to
give an offset to the room thermistor value measured by the user
interface used as room thermostat or by the external room sensor.
The settings can be used to compensate for situations where the
user interface used as room thermostat or the external room sensor
CANNOT be installed on the ideal installation location (see
"5.7 Setting up an external temperature sensor" on
#
Code
[1.6]
[2-0A]
Room sensor offset (user interface used
as room thermostat): Offset on the actual
room temperature measured on the user
interface used as room thermostat.
▪ –5°C~5°C, step 0.5°C
[1.7]
[2-09]
Room sensor offset (external room
sensor option): ONLY applicable if the
external room sensor option is installed
and configured.
▪ –5°C~5°C, step 0.5°C
8.4.3

Main zone

Setpoint screen
You can set the leaving water temperature for the main zone using
the setpoint screen. For more information about how to do this, see
"8.3.5 Setpoint screen" on
page 43.
Schedule
Indicates if the desired leaving water temperature is according to a
schedule. Influence of the LWT setpoint mode [2.4] is as follows:
▪ In Fixed LWT setpoint mode, the scheduled actions consist of
desired leaving water temperatures, either preset or custom.
▪ In Weather dependent LWT setpoint mode, the scheduled actions
consist of desired shift actions, either preset or custom.
#
Code
[2.1]
N/A
Schedule
▪ 0: No
▪ 1: Yes
Heating schedule
You can set the main zone heating temperature schedule using the
schedule screen. For more information about this screen, see
"8.3.8 Schedule screen: Example" on
Cooling schedule
You can set the main zone cooling temperature using the schedule
screen. For more information about this screen, see
screen: Example" on
page 44.
Setpoint mode
In Fixed mode, the desired leaving water temperature does NOT
depend on the outdoor ambient temperature.
EPGA11~16DAV3 + EAVH/X16S18+23DA6V+9W
Daikin Altherma – Low temperature split
4P556070-1 – 2018.10
Description
page 21).
Description
Description
page 44.
"8.3.8 Schedule
In WD heating, fixed cooling mode, the desired leaving water
temperature:
▪ depends on the outdoor ambient temperature for heating
▪ does NOT depend on the outdoor ambient temperature for cooling
In Weather dependent mode, the desired leaving water temperature
depends on the outdoor ambient temperature.
#
Code
[2.4]
N/A
Setpoint mode
▪ 0: Fixed
▪ 1: WD heating, fixed cooling
▪ 2: Weather dependent
When weather dependent operation is active, low outdoor
temperatures will result in warmer water and vice versa. During
weather dependent operation, the user has the possibility to shift the
water temperature up or down by a maximum of 10°C.
Heating WD curve
Set weather-dependent heating for the main zone (if [2.4] = 1 or 2):
#
Code
[2.5]
[1-00]
Set weather-dependent heating:
T t
[1-01]
[1-02]
[1-02]
[1-03]
[1-03]
▪ T
: Target leaving water temperature
t
(main zone)
▪ T
: Outdoor temperature
a
▪ [1-00]:
temperature. –40°C~+5°C
▪ [1-01]:
temperature. 10°C~25°C
▪ [1-02]:
temperature
temperature equals or drops below the
low
[9‑01]°C~[9‑00]°C
Note: This value should be higher
than
temperatures
required.
▪ [1-03]:
temperature
temperature equals or rises above the
high
[9‑01]°C~min(45, [9‑00])°C
Note: This value should be lower than
[1‑02]
temperatures less warm water is
required.
Cooling WD curve
Set weather-dependent cooling for the main zone (if [2.4] = 2):
8 Configuration
Description
Description
[1-00]
[1-01]
T a
Low
outdoor
ambient
High
outdoor
ambient
Desired
leaving
water
when
the
outdoor
ambient
temperature.
[1‑03]
as
for
low
outdoor
warmer
water
is
Desired
leaving
water
when
the
outdoor
ambient
temperature.
as
for
high
outdoor
Installer reference guide
47