6. ELECTRIC MECHANISM
Circuit board connectors
<Main circuit board>
P1 [FAN2]
Pin No.
1
+24V
2
FAN2 signal
3
0V
P3 [SYNC]
Pin No.
1
+5V
2
Encoder signal
3
Needle up stop position signal
4
Needle down stop position signal
5
0V
P4 [PANEL]
Pin No.
1
+5V
2
0V
3
KEY0
4
KEY1
5
KEY2
6
OC
7
A
8
B
9
C
10
D
11
E
12
F
13
G
14
STB
15
P8V
16
SENSOR
17
BUZZER
18
0V
19
0V
20
0V
6 - 6
Signal name
Signal name
Signal name
Symptoms resulting mainly from poor contact
The inside air circulation fan does not operate.
Error E-41 is displayed.
Symptoms resulting mainly from poor contact
The machine motor does not turn.
A machine stopping error occurs.
One of error E-02, E-62, E-63 and E-64 is displayed.
Symptoms resulting mainly from poor contact
The panel does not operate.