Aqua Lung EA-4500 LW Technical Manual page 14

Survival egress air
Table of Contents

Advertisement

14
27. Grab one wire at a time with the tapered pliers and bend
it to the side at a 90 degree angle. Trim the ends of the wire
evenly to approximately 1 inch.
28. Grasp both ends of the safety wire (36) with the tapered
pliers and engage the locking mechanism. Pull the center
knob Two Full Rotations (6-8 turns per inch) to twist the
safety wire. Disengage the locking mechanism and remove
tapered pliers from safety wire. Trim the ends of the safety
wire (½ - ¾ inches) enough to fit in the space between the
LP / HP module body (8 & 13).
29. Grasp the twisted end of the safety wire (36) with the
tapered pliers and bend the safety wire 180 degrees to the
opposite side. Using the end of the flat brass o-ring tool,
push the safety wire all the way into the space between the
LP / HP module body (8 & 13) .
WARNING:
Failure to push the safety wire all the way
into the space between the LP / HP module body can
cause bodily injury due to sharp edges.
SEA-3000 LW & SEA-4500 Technical Manual
30. Install first stage cover (1) onto the LP module body (8).
Loosely fasten the strap clamp (60) into the groove at the
base of the first stage cover. Align the strap clamp with the
fill port and pull tight. Trim the excess strap flush with the
tab using diagonal pliers.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ea-3000 lw

Table of Contents