13. Install the retainer ring (45) into the box bottom (59).
Insert the pin spanner on the 5 in 1 tool into the slots of
the retainer ring and screw it into the box bottom hand-
tight. Ensure the front cover (46) slots have remained in
a horizontal position. Screw the purge cover (44) onto the
box bottom until hand-tight.
14. Install the mouthpiece (61) onto the box bottom (59).
Loosely fasten a strap clamp (60) into the groove at the base
of the mouthpiece with the tab on the MP hose side. Pull the
strap clamp tight and trim the excess strap flush with the tab
using diagonal pliers.
NOTE: The mouthpiece can be adjusted to several
different user preferred positions. (Reference the
User's Manual for more information).
15. Refit the hose (38) onto the second stage and tighten the
hose nut by hand until it stops. DO NOT use any tools to tighten
the hose nut onto the inlet fitting (55). Audible clicks should
be heard as the hose nut is tightened into place. Check the
hose nut is locked into place and cannot be loosened without
squeezing the locking slide ring (58).
SEA-3000 LW & SEA-4500 Technical Manual