Service guide

Introduction
The dehumidifier requires very little attention for trouble free running. All the necessary
safety and control functions have been built in. The fan motor(s) and the compressor
have permanent lubrication and require no particular maintenance.
Monthly service
The air inlet filter is to be cleaned once a month. The filter is placed in a stand behind
the grille in the air inlet duct.
Please follow this procedure to perform the monthly service:
Step
Annual service
The dehumidifier should be inspected once a year. Please follow this procedure to
perform the annual service:
Step
1
Remove the grill from the duct and take out the filter
2
Wash the filter in tepid soapy water or vacuum clean thoroughly
3
Put the filter back in the filter stand and fasten the grille to the duct
1
Remove the front from the dehumidifier
2
Inspect the inside of the dehumidifier
3
Vacuum clean the dehumidifier to remove any dust or debris
Important: Vacuum clean the condenser thoroughly
4
Wash if necessary the lamella evaporator in tepid soapy water if it is badly
soiled
Action