• Terminal blocks represent the most common application. Please check the application table first
The r
•
elay output are line voltage, they are connected with line voltage internally inside thermostat
The OC
•
C terminal can assume different meaning depending on parameter 17 setting
• The functionality of the remote NTC is depending by P25 and P16 parameters
Alarm Code Description
Item
Code
1
E1
2
E2
3
HI
4
LO
5
E3
6
E4
7
E5
· E3,E4 only available for 2-pipe, auto mode enabled.
·
icon will twinkle if there is filter alarm
·
symbol will flash if there are communication fault
COM
· If the remote sensor is enabled, the E1/E2 warning will be ignored. If E1/E2 warning happened, T7000 will shut off the fan and close the valve.
T7600-
TB21-
Parameter
...JA0
ECM Max voltage
ECM cut off relay
■
■
Restart after power failure
■
■
Keypad lock
■
■
Default display
■
Auto changeover
■
■
Digital input function
■
■
Unit selection
■
■
Temperature offset
■
Fan speed
■
■
Language
■
Mode selection
■
■
Back light
■
■
Remote sensor type
■
■
MODBUS address
■
■
Baud rate
■
Sample time
■
■
Deadband
■
KP
■
KI
TiO2/ESP operation
Inter stage difference
Heating stage
Internal sensor shorted warning
Internal sensor opened warning
High temperature warning. Room Temperature > 55℃
Low temperature warning. Room Temperature < 0℃
Remote sensor shorted
Remote sensor opened
Dew point risk warning
Function
Max voltage above which the fan output is 100%, range 0-10V.
00: Disabled; 01: Enabled
00: keep last status; 01: on; 02: off
00: no lock;
01: lock all keys;
02: lock the keys except fan speed and temp. adjustment;
03: lock on/off and general;
04: lock the keys except on/off
00: display room temp.; 01: display set point only
00: disable; 01: enable (When 2 pipe requires 10K NTC on water tube) 00
00: open indicates key card is inserted (occupied), closed indicates key
card is pulled out (unoccupied);
01: closed indicates key card is inserted (occupied), open indicates key
card is pulled out (unoccupied);
02: closed indicates dew point risk, open indicates no dew point risk;
03: open indicates dew point risk, closed indi-cates no dew point risk;
04: open indicates occupied, closed indicates unoccupied, shut off fan
and valve;
05: closed indicates filter alarm; 06: open indicates filter alarm
00: Celsius degree (℃); 01: Fahrenheit degree (
o
Setting range –5~5℃(-9~9
F)
00: 3 speed;
01: 2 speed (wiring MED, LOW);
02: 1 speed (wiring LOW);
03: no fan
00: Chinese; 01: English
00: cooling/heating/ventilation; 01: cooling only; 02: heating
The back light will be OFF in 05 ... 60 Sec
00: China market 10KNTC; 01: JCI type II 10kNTC
1-64
00: 9600; 01: 4800
Setting range 1~99s
Setting range 0~10℃
Setting range 1~99
Setting range 0~99
00: operate separately (corresponding button); 01: work with FCU fan
Setting range 0~10℃
00: 2 stage; 01: 1 stage
Description
4
Default
10V
00
00
00
00
00
o
F)
00
0
00
00
00
30
00
1
00
10
1
10
01
00
3
00