Si041254EE
Step
7
Disconnect the
connector [S1].
8
Disconnect the
connectors [S6] and
[S8].
9
Remove the screw of
the electrical box.
10
Unfasten the hook at
the back of the
electrical box.
11
Pull out the electrical
box.
Removal Procedure
Procedure
[S1]: fan motor
[S1]
(R2774)
[S6]: swing motor for horizontal
blades
[S8]: swing motor for vertical
[S6]
blades
Some models do not have
the harness for [S8].
[S8]
(R2775)
Electrical box
(R3205)
Hook
When reassembling, make
sure that the hook at the
back of the electrical box is
fastened.
(R17665)
Electrical Box
Points