5. Electrical Box

Warning
Step
Remove the screw of
1
the wire fixture.
2
Remove the 4 screws
of the terminal board
and disconnect the
connecting wires.
Disconnect the
3
connector [S6].
4
Disconnect the
connector [S7].
Remove the screw and
5
remove the drip proof
plate.
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Electrical box
Terminal
board
Connecting
wire
Wire fixture
(R17926)
[S6]: swing motor
[S7]: AC fan motor
[S7]
Put any excess wires behind
[S6]
the power supply lead wire.
DC fan motor models have
no harness for [S7].
(R17202)