Fan Motor - Daikin FTKD25GVM9 Service Manual

Removal procedure, 2.0/2.5/3.5 kw class, 9000/13000 btu/h class
Table of Contents

Advertisement

Si041251EC

8. Fan Motor

Warning
Step
Release the fan motor
1
lead wires from the
hooks.
2
Remove the screw of
the fan rotor.
3
Remove the 2 screws
of the fan motor fixing
plate.
4
Unfasten the hook (a)
of the fan motor fixing
plate.
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
(R4389)
(R4390)
Fan motor
fixing plate
Hook (a)
(R20215)
Fan Motor
Points
15