Daikin FTKS09HV2S Service Manual page 38

Removal procedure, 2.0/2.5/3.5/4.6 kw class, 9000/12000 btu/h class
Table of Contents

Advertisement

Removal of Fan Motor
Step
2
Loosen the lock screw
and remove the fan
motor.
Press the bearing
3
ASSY from outside.
Remove the bearing.
4
36
Procedure
Lock screw
When reassembling the fan
motor and the fan rotor,
provide as much as 5 mm of
play between the side face
of the rotor and the bottom
frame.
Fan motor
Side face of rotor
(R8120)
(1) Insert the fan motor with
(R8121)
approx. 5 mm left.
(2) Tighten the screw until it
stops. Then give the screw
one more turn.
(3) Rotate the fan rotor and
confirm the fan motor and
the fan rotor are installed
appropriately.
(4) Tighten the screw
completely if appropriate.
(R8122)
(5) If not appropriate, go back to
(1).
Si041137
Points
Side face of
bottom frame
5 mm
(R2808)
(R9582)
Removal Procedure

Hide quick links:

Advertisement

Table of Contents
loading