Daikin FTKS09HV2S Service Manual page 34

Removal procedure, 2.0/2.5/3.5/4.6 kw class, 9000/12000 btu/h class
Table of Contents

Advertisement

Removal of Indoor Heat Exchanger
Step
2. Remove the indoor heat
exchanger.
1
Detach the indoor unit
from the installation
plate.
Unfasten the hook of
2
the piping fixture at the
back of the indoor unit.
Remove the piping
fixture.
3
Slightly widen the
auxiliary piping.
Remove the 2 screws
4
on the left side.
32
Procedure
Piping
fixture
(R10622)
(R17120)
Caution
When removing or
reassembling the indoor heat
exchanger, be sure to wear
gloves or wrap the indoor
heat exchanger with cloth.
(You may be injured by the
fins.)
(R10546)
Si041137
Points
Removal Procedure

Hide quick links: