Download Print this page

Follett Maestro Plus P425 Installation Instructions Manual page 12

Module into follett symphony fb; follett symphony ct; follett symphony ci

Advertisement

CT Units - 25/50/110CT425A
Remove Ice Machine Module
1. Disconnect power from unit, turn off water
supply, and remove side panels.
2. Remove existing module.
3. On new ice machine, remove the
top bearing insulation (Fig. 1.1) and
compression nozzle insulation (Fig. 1.2).
Note: Retain ice transport tube and hose
clamp.
4. On new ice machine, remove the ice
machine electrical box cover and set DIP
switches (Fig. 2).
5. Reinstall ice machine electrical box cover.
12
Maestro Plus P425/CP425/EP425 Ice Machine for Symphony FB, CT, and CI Dispensers
Fig. 1
1
Fig. 2
OFF POSITION
Replacement P425A/W installed in Symphony dispenser
OFF
Sleep cycle
disabled
Not used
Sleep cycle
dispense duration
20 min. time delay
Flush disabled
Maint. timer ON
Sleep cycle dispense duration
OFF
ON
2
ON POSITION
4
ON
Sleep cycle
enabled
Not used
Sleep cycle
dispense duration
60 min. time delay
Flush enabled
Maint. timer OFF
35 s
15 s
60 s

Advertisement