Aeroflex RGS-2000NG Getting Started Manual

Aeroflex RGS-2000NG Getting Started Manual

Tcas test set
Hide thumbs Also See for RGS-2000NG:

Advertisement

RGS-2000NG
TCAS Test Set
Getting Started Manual
Issue-4
EXPORT CONTROL WARNING: This document contains controlled technical data under the jurisdiction
of the Export Administration Regulations (EAR), 15 CFR 730-774. It cannot be transferred to any foreign
third party without the specific prior approval of the U.S. Department of Commerce, Bureau of Industry
and Security (BIS). Violations of these regulations are punishable by fine, imprisonment, or both.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RGS-2000NG and is the answer not in the manual?

Questions and answers

Summary of Contents for Aeroflex RGS-2000NG

  • Page 1 RGS-2000NG TCAS Test Set Getting Started Manual Issue-4 EXPORT CONTROL WARNING: This document contains controlled technical data under the jurisdiction of the Export Administration Regulations (EAR), 15 CFR 730-774. It cannot be transferred to any foreign third party without the specific prior approval of the U.S. Department of Commerce, Bureau of Industry...
  • Page 2 Getting Started Manual PUBLISHED BY Aeroflex COPYRIGHT  Aeroflex 2016 All rights reserved. No part of this publication m ay be reproduced, stored in a retrieval system , or transm itted in any form or by any m eans, electronic, m echanical, photocopying, recording or otherwise without the prior perm ission of the publisher.
  • Page 3 R G S - 2 0 0 0 N G G e t t i n g S t a r t e d M a n u a l This m anual contains essential inform ation relating to initial use of the Unit. Aeroflex recom m ends the operator becom e fam iliar with the Operation Manual contained on the accom panying CD-ROM.
  • Page 4 For continued EMC com pliance, all external cables m ust be shielded and 3 m eters or less in length. Nomenclature Statement In this m anual, RGS-2000NG, Test Set or Unit refers to the RGS-2000NG TCAS Test Set. Declaration of Conformity The Declaration of Conform ity Certificate included with the Unit should rem ain with the Unit.
  • Page 5 2 environm ent. The equipm ent is designed to operate from installation supply Category II. IDENTIFIES CONDITIONS OR ACTIVITIES The RGS-2000NG should be protected from liquids such as THAT, IF IGNORED, CAN RESULT IN spills, leaks, etc. and precipitation such as rain, snow, etc.
  • Page 6 R G S - 2 0 0 0 N G G e t t i n g S t a r t e d M a n u a l Case, Cover or Panel Removal Pow er Cords The AC Power Cord included with the Test Set, or an appropriate replacem ent, should be used to connect the Test Opening the Case Assem bly exposes the operator to Set to a grounded AC power supply.
  • Page 7 R G S - 2 0 0 0 N G G e t t i n g S t a r t e d M a n u a l Toxic Hazards EM I (Electromagnetic Interference) SOM E OF THE COM PONENTS USED IN SIGNAL GENERATORS CAN BE A SOURCE THIS EQUIPM ENT M AY INCLUDE RESINS OF ELECTROMAGNETIC INTERFERENCE...
  • Page 8 R G S - 2 0 0 0 N G G e t t i n g S t a r t e d M a n u a l Toxic Hazards (cont) BERYLLIA BERYLLIUM COPPER BERYLLIA (BERYLLIUM OXIDE) IS USED IN SOM E M ECHANICAL COM PONENTS W ITHIN THE CONSTRUCTION OF SOM E OF THE THIS INSTRUM ENT ARE M ANUFACTURED...
  • Page 9: Table Of Contents

    R G S - 2 0 0 0 N G G e t t i n g S t a r t e d M a n u a l Static Sensitive Components Table of Contents Service Upon Receipt of Material ........7 Unpacking..............
  • Page 10: Service Upon Receipt Of Material

    TOP PACKING Special-design packing m aterial inside the shipping container MOLD provides m axim um protection for the RGS-2000NG. Avoid dam aging the shipping container and packing m aterial during equipm ent unpacking. Use the following steps to unpack the Test Set:...
  • Page 11: Checking Unpacked Equipment

    114114 em ail: am ericas.service@aeroflex.com Refer to the RGS-2000NG Operation Manual for Optional Item s available for the RGS-2000NG TCAS Test Set. S ubj ect to E xpor t C ontr ol , see C over P age for detai l s.
  • Page 12 R G S - 2 0 0 0 N G G e t t i n g S t a r t e d M a n u a l RGS-2000NG M anual, Getting Started M anual, Operation Pow er Cable (AC)
  • Page 13: Specifications

    R G S - 2 0 0 0 N G G e t t i n g S t a r t e d M a n u a l SPECIFICATIONS (S peci fi cati ons ar e subj ect to change w i thout noti ce. ) PHYSICAL AC INPUT POW ER Overall Dimensions...
  • Page 14: Installation

    Replace any standard two-prong receptacle(s) with 3.1.C Ventilation properly grounded three-prong receptacle(s). The RGS-2000NG is air-cooled by fans that draw air through 3.1.E Operating Safety vents in the case. Do not onstruct the air vents while the instrum ent is in use. Avoid standing the instrum ent on or DUE TO POTENTIAL FOR ELECTRICAL close to other equipm ent that is hot.
  • Page 15: Installation Procedure

    Paint exposed m etal surface to avoid corrosion. 3.2.B Rack Mount Contact Aeroflex for inform ation on installing the RGS-2000NG in a rack. S ubj ect to E xpor t C ontr ol , see C over P age for detai l s.
  • Page 16: Front Panel

    R G S - 2 0 0 0 N G G e t t i n g S t a r t e d M a n u a l Front Panel Controls, Connectors and Rear Panel Connectors Indicators (cont) Refer to Num erical Reference Charts for connector cross- reference.
  • Page 17: Rear Panel

    (Typically used with a Spectrum Pow er Sw itch Connects (I) or disconnects (O) Analyzer.) external AC power from the EXTERNAL Used for I/O applications with RGS-2000NG. external equipm ent. PULSE M ODULATION Connectors SCOPE Used for testing of the UUT.
  • Page 18: Power On/Off Procedures

    Verify the Power Switch Indicator illum inates. W ait while the Test Set com pletes the power-up sequence. The RGS-2000NG Main Menu is displayed. Pow er OFF Test Set S T E P P R O C E D U R E Press the Power Switch (Front Panel) to power OFF the Test Set.
  • Page 19: Touch Screen

    R G S - 2 0 0 0 N G G e t t i n g S t a r t e d M a n u a l TOUCH SCREEN SCREEN FEATURES AND ICONS The RGS-2000NG contains a resistive Touch Screen that is responsive to the touch of a hum an finger. Gloves can be worn when utilizing the Touch Screen or a writing instrum ent (e.g.
  • Page 20 R G S - 2 0 0 0 N G G e t t i n g S t a r t e d M a n u a l SCREEN FEATURES AND ICONS (cont) Icon Description Icon Description External equipm ent is connected to the An error has occurred.
  • Page 21 R G S - 2 0 0 0 N G G e t t i n g S t a r t e d M a n u a l SCREEN FEATURES AND ICONS (cont) Feature Description Feature Description Local Mode - All controls on the Norm al Mode - Controls are m odified Touchscreen are enabled.
  • Page 22: Menus And Screens

    R G S - 2 0 0 0 N G G e t t i n g S t a r t e d M a n u a l MENUS AND SCREENS M ain M enu TCAS M enu ( T h i s s c r e e n i s a r e p r e s e n t a t i o n o f t h e s c r e e n t h a t a p p e a r s .
  • Page 23 R G S - 2 0 0 0 N G G e t t i n g S t a r t e d M a n u a l MENUS AND SCREENS (cont) Transponder M enu UAT M enu ( T h i s s c r e e n i s a r e p r e s e n t a t i o n o f t h e s c r e e n t h a t a p p e a r s .
  • Page 24 R G S - 2 0 0 0 N G G e t t i n g S t a r t e d M a n u a l MENUS AND SCREENS (cont) Support M enu System M enu ( T h i s s c r e e n i s a r e p r e s e n t a t i o n o f t h e s c r e e n t h a t a p p e a r s .
  • Page 25 We reserve the right to make design changes without notice. Go to http://ats.aeroflex.com/contact/sales-distribution for Sales and Service contact information. EXPORT CONTROL WARNING: This document contains controlled technical data under the jurisdiction of the Export Administration Regulations (EAR), 15 CFR 730-774.