Seawind 1000XL2 Owner's Manual page 19

Cruising catamaran
Table of Contents

Advertisement

Owners Handbook
Troubleshooting
Green light not on
YES
Motor running
YES
Runs 10 min only and turns
off yellow light now on
NO
Leave running
after 30 min note if fan is
cycling
YES
Put thermometer in empty freezer against wall away from fridge and monitor
maximum and minimum temperatures
Note freezer temperature should fall at about 4 degrees an hour untill eutectic point
where it will slow untill unit turns off expect 16 hrs for full pull down time
Freezer Temperatures should be about -11 maximum when motor starts
new cycle and pull down to -14 ~ -16 minimum degree C at end of cycle
Fridges temperatures should be about 1 maximum when motor starts
new cycle and pull down to -2 ~ -4 minimum degree C at end of cycle
To warm
Possible causes
(1) Ventilation blocked
(2) Condenser fan setting to high
(3) Suction thermistor turning off too soon
(4) Motor speed too low
Is motor running
NO
YES green light faulty
Bridge terminals T & C on danfoss controller Motor runs
NO
YES
NO
Disconnect fan wires and check directly across 12 v
dc
supply if okay reconnect fan now bridge terminals 1
&2 does fan go
YES
Replace thermistor on
condenser
NO
YES return ICEER
grey controller for
repair
bridge terminals 5 & 6
Check fan can spin freely
YES
Is Condenser hot 47 degrees C
YES
NO
Return ICEER grey controller for repair
To Cold
Possible causes
(1) Condenser fan setting to low
(2) Suction thermistor not turning off
(3) Low on gas 134A 100 gram
19
Check power to fridge and wires
into on off switch
Try bridging terminals 7& 8 on terminal strip
check voltage at danfoss controller
If no success return ICEER grey controller fo
repair
NO Try replacement
danfoss controller
Retest if it runs past 10 min replace
thermistor on suction line. If it still turns off
return ICEER controller for repair
Fan body is not twisted in
motor bay stopping fan or
NO
loose wire jamming blades
Low on gas or blocked
NO
capillary note current draw
should be low also might
be too lower motor speed
Contact ICEER for further
action

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Seawind 1000XL2