HEATING PERFORMANCE DATA
MODEL: GSH130361A* / ARUF49-00*-1* / ARUF36421A*
65
60
55
MBh
40.2
38.1
35.8
Delta T
29.2
27.7
26.0
KW
2.90
2.84
2.79
AMPS
13.0
12.1
11.3
COP
4.07
3.92
3.76
EER
13.9
13.4
12.9
HI PR
230
221
212
LO PR
80
74
70
MODEL: GSH130421A* / ARUF49-00*-1* / ARUF36421A*
65
60
55
MBh
49.0
46.4
43.7
Delta T
30.3
28.6
27.0
KW
3.59
3.52
3.46
AMPS
16.7
15.5
14.5
COP
4.00
3.86
3.70
EER
13.7
13.2
12.6
HI PR
237
227
218
LO PR
75
70
65
MODEL: GSH130481A* / ARUF61-00*-1* / ARUF48601A*
65
60
55
MBh
54.1
51.2
48.2
Delta T
31.3
29.6
27.9
KW
3.84
3.77
3.70
AMPS
18.1
16.8
15.7
COP
4.12
3.98
3.81
EER
14.1
13.6
13.0
HI PR
224
215
207
LO PR
74
69
64
High pressure is measured at the suction service valve ( the larger valve).
Low pressure is measured at the gauge port connection.
Calculations are based on nominal CFM and 70 °F indoor dry bulb.
EXPANDED PERFORMANCE DATA
Outdoor Ambient Temperature
50
47
45
40
33.5
32.0
31.0
28.8
24.3
23.2
22.5
20.9
2.73
2.70
2.68
2.63
10.7
10.3
10.1
9.5
3.59
3.46
3.39
3.21
12.3
11.8
11.6
11.0
203
198
194
187
64
60
58
54
EXPANDED PERFORMANCE DATA
Outdoor Ambient Temperature
50
47
45
40
40.8
39.0
37.8
35.1
25.2
24.1
23.3
21.7
3.39
3.35
3.32
3.26
13.6
13.1
12.9
12.1
3.53
3.41
3.33
3.15
12.1
11.6
11.4
10.8
209
204
200
192
60
57
54
50
EXPANDED PERFORMANCE DATA
Outdoor Ambient Temperature
50
47
45
40
45.0
43.0
41.7
38.7
26.1
24.9
24.1
22.4
3.63
3.59
3.56
3.49
14.8
14.3
14.0
13.2
3.63
3.51
3.43
3.24
12.4
12.0
11.7
11.1
198
193
189
182
59
56
54
49
35
30
25
20
26.6
19.9
18.4
16.9
19.3
14.5
13.4
12.3
2.58
2.42
2.37
2.32
9.1
8.7
8.3
7.9
3.02
2.41
2.27
2.14
10.3
8.2
7.8
7.3
179
172
164
158
48
43
38
34
35
30
25
20
32.4
28.7
26.5
24.4
20.0
17.7
16.3
15.0
3.19
3.08
3.01
2.95
11.5
11.0
10.5
10.0
2.97
2.72
2.57
2.42
10.1
9.3
8.8
8.3
184
177
169
162
45
40
36
32
35
30
25
20
35.7
33.6
31.1
28.6
20.7
19.5
18.0
16.5
3.42
3.34
3.27
3.20
12.5
12.0
11.5
10.9
3.05
2.95
2.78
2.62
10.4
10.1
9.5
8.9
175
167
160
154
44
40
35
31
HEATING OPERATION
17
15
10
5
16.0
15.4
13.8
12.3
11.6
11.2
10.0
8.9
2.29
2.27
2.22
2.17
7.7
7.6
7.3
6.8
2.05
1.99
1.82
1.65
7.0
6.8
6.2
5.7
154
151
145
140
31
30
26
22
HEATING OPERATION
17
15
10
5
23.0
22.1
19.9
17.6
14.2
13.7
12.3
10.9
2.91
2.88
2.82
2.75
9.8
9.7
9.2
8.6
2.31
2.25
2.06
1.87
7.9
7.7
7.1
6.4
158
155
149
144
29
28
24
21
HEATING OPERATION
17
15
10
5
27.0
26.0
23.3
20.7
15.6
15.0
13.5
12.0
3.16
3.13
3.06
3.00
10.7
10.5
10.0
9.3
2.50
2.43
2.23
2.02
8.5
8.3
7.6
6.9
150
147
142
136
29
28
24
20
AMPS = Outdoor unit amps (comp.+fan)
KW = Total system power
0
-5
-10
10.7
9.1
7.5
7.8
6.6
5.4
2.12
2.07
2.02
6.4
5.9
5.4
1.48
1.29
1.08
5.0
4.4
3.7
134
129
125
19
16
13
0
-5
-10
15.4
13.1
10.7
9.5
8.1
6.6
2.69
2.62
2.56
8.1
7.4
6.7
1.67
1.46
1.23
5.7
5.0
4.2
138
133
128
17
15
12
0
-5
-10
18.0
15.4
12.6
10.4
8.9
7.3
2.93
2.86
2.79
8.8
8.1
7.3
1.80
1.58
1.32
6.2
5.4
4.5
131
126
121
17
15
12
39