Installation And Wiring; Mounting The Module - Curtis 1356 Manual

Can expansion modules
Table of Contents

Advertisement

2 — INSTALLATION & WIRING
2
+
C A U T I O N
Fig. 2
Mounting
dimensions, Curtis 1356
and 1356P expansion
modules.
4

INSTALLATION AND WIRING

MOUNTING THE MODULE

The outline and mounting hole dimensions for the modules are shown in Fig. 2.
The 1356P module should be mounted using two M4 screws.
The 1356 module requires the OEM to develop an appropriate case to
provide environmental protection. Mounting for the 1356 depends on the case.
Care should be taken to prevent contaminating the PCBA (1356) or
connector (1356P). In order to prevent external corrosion and leakage paths
from developing, the mounting location should be carefully chosen to keep
the module as clean and dry as possible.
1356
3.8
60.7
3.8
70.0
62.4
1
13
J1 CONNECTOR
1356P
J1 CONNECTOR
1
13
Dimensions in millimeters.
Curtis 1356/1356P CAN Expansion Module Manual,
100.0
92.4
5X Ø3.50
STATUS
LEDs
12
1 2
24
3
4
4XR3
J2 CONNECTOR
J2 CONNECTOR
12
1
2
24
3
4
110.0
116.0
126.0
16.3
14.4 ±1.5
1.60
4xR8
2x Ø4.50
25.0
80.0
32.0
5.0
17.0
25.0
Rev. A

Advertisement

Table of Contents
loading

This manual is also suitable for:

1356p