7 — PROGRAMMER: MONITOR MENUS
50
ALLOWABLE
PARAMETER
RANGE
-2
2
29
Pulse Counts
4
0 – 65535 rpm
RPM
-32.768 – 32.767 m
Position
POWER SUPPLY OUTPUT MONITOR MENU
ALLOWABLE
PARAMETER
RANGE
0.0 – 6.3 V
+5V
0.0 – 16.0 V
+12V
0 – 250 mA
EXT Current
BATTERY VOLTAGE MONITOR MENU
ALLOWABLE
PARAMETER
RANGE
0.0 – 120.0 V
Battery Voltage
ALLOWABLE
PARAMETER
RANGE
0 – 65535 h
Hours
0 – 59 min
Minutes

Fault Menu

The Curtis programmer provides a convenient way to access fault information;
see Section 6: Faults and Diagnostics. The programmer displays the faults by
name. It displays all faults that are currently set and also a history of all the
faults that have been set since the history log was last cleared.
Curtis 1356/1356P CAN Expansion Module Manual,
ENCODER MONITOR MENU
DESCRIPTION
-1
Current encoder pulse counts.
29
Negative counts indicate the encoder is running
in the reverse direction of the zero position.
Displays RPM, when the encoder type
is configured as RPM mode.
Displays position, when the encoder type
is configured as Position mode.
Negative counts indicate the encoder ia running
in the reverse direction of the zero position.
DESCRIPTION
Voltage of the +5V output.
Voltage of the +12V output.
Combined current of the external +12V and +5V
power supplies.
DESCRIPTION
Voltage of the battery.
HOUR METER MONITOR MENU
DESCRIPTION
Present hours of the hour meter. The hour meter
runs all the time the 1356 /1356P is powered on.
Present minutes of the hour meter.